ページ17 – GReddy Profec User Manual
Page 18
1
2
3
Inspection after Installation
Important
Please read carefully
Operations
(1) Check for good connections between the Power harness, Valve unit and Control
unit.
(2) Reinstall factory parts as needed.
(3) Double check all harnesses and hoses for proper installation.
(4) Reattach the negative terminal to the battery.
(5) Start the engine and confirm the Profec controls and display are functional.
(6) While the engine is idling, confirm the Profec recognizes vacuum pressure.
(7) Double check hoses for air leaks.
・Shut down the vehicle, if any problems occur.
・Refer to the Profec Test mode, to troubleshoot.
・Refer to page 18 and 39 for the Test mode and Troubleshooting the Profec.
Basic operation
Control unit
1. SELECT switch
- Push: SELECT to toggle between BOOST HI - BOOST LO.
- Push & Hold-down: SELECT to Power ON or OFF.
2. MODE switch
- Push : MODE to toggle between the Real-time (boost gauge) display and a
set-up screen. While in the SETUP mode screen, pushing MODE will cancel
the changes made.
- Push & Hold-down: MODE to reset the recorded peak value.
3. SET DIAL
- Turn : SET DIAL to change the settings and to scroll through menus. In
Real-time (boost gauge) mode, it activates a shortcut to changing the SET%
value.
- Push : SET DIAL to confirm program settings. In Real-time (boost gauge)
mode, switch from LO or HI mode to SCRAMBLE mode.
Important
・Please use care when operating the SET DIAL. Be careful not to use excessive
force on the controls.