3 corrective maintenance, 3 corrective maintenance -5 – EOTech LWTS Light Weapon Thermal Sight User Manual
Page 69

3-5
3.3 CORRECTIVE MAINTENANCE
The LWTS
has no internal parts or assemblies replaceable
by the user or organizational level personnel. Refer to
section 3.4 regarding maintenance and/or repair actions
beyond those described in this manual.
Throw-Lever Tension Adjustment
The throw-lever mounting bracket has a locknut that adjusts
the tension required to clamp it to the weapon rail. It is
preset at the factory but may need adjustment when initially
mounted to the rail of the host weapon. If adjustment is
required, the following procedures apply and are performed
with the LWTS removed from the host weapon:
CAUTION
Creating too much tension with the locknut may
result in damage to the mounting bracket when the
throw-lever is forced against the weapon rail.
Creating too little tension with the locknut may
allow for movement of the LWTS on the rail.
Never completely remove the locknut from the
mounting bracket.
1. Swing the throw-lever closed (against the body of the
LWTS), then push in the lever lock to engage the locking
mechanism.
2. Using the provided 3/8” box wrench, adjust the locknut
using slight movements (2 or 3 degrees). Turning the
locknut counterclockwise will decrease tension on the
throw-lever. Turning it clockwise will increase tension on
the throw-lever.