3-1
CHAPTER 3
MAINTENANCE AND SERVICING
SECTION I
MAINTENANCE AND TROUBLESHOOTING
3.1 TROUBLESHOOTING
The procedures below will help correct some of the basic
problems that may arise with the LWTS. If the equipment
malfunction is not listed, or the actions listed do not correct
the fault, refer to section 3.4 for additional guidance.
Table 3-1. Troubleshooting Procedures.
Symptom
Malfunction
Corrective Action
1. No display is
present upon
start-up.
a. LWTS is in Standby
Mode.
a. Press any button to “wake”
from Standby Mode
(section 2.7).
b. Improperly adjusted
settings.
b. Reset LWTS to factory
default parameters
(section 2.8).
c. Software overload.
c. Cycle LWTS power on/off
(section 2.7).
d. Battery power is low or
batteries not properly
installed.
d. Install fresh batteries
(section 2.2).
e. Battery compartment
requires cleaning.
e. Clean battery compartment
(section 3.2).
f. Battery contacts of
battery pack require
cleaning.
f. Clean battery contacts of
battery pack (section 3.2).