8 system reset, 8 system reset -12 – EOTech LWTS Light Weapon Thermal Sight User Manual
Page 30

2-12
2.7 POWER (Continued)
Pressing any button will reactivate the unit. Upon “waking”
from Standby Mode, the unit will retain all settings entered
by the operator prior to being placed in standby.
Power Down
To power down the LWTS, press and hold the
ON/OFF/STANDBY button. The device will shut down in
approximately 4 seconds after the STANDBY?, STANDBY!,
and POWER OFF messages appear sequentially in the
eyepiece display. Release the button when the eyepiece
display turns dark.
2.8 SYSTEM RESET
Simultaneously pressing both the FOV/MODE and
POL/AGC buttons resets the LWTS to the following default
parameters:
a. Operational mode is set to CLIP ON (see section 2.24)
b. Polarity is set to WHT HOT (see section 2.13)
c. FOV is set to WFOV (see section 2.14)
d. Display brightness (LED) is set to mid-scale (see
section 2.21)
e. Thermal brightness (LVL) is set to mid-scale (see
section 2.9)
f. Video I/O is set to I/O OUT (see section 2.23)
g. AGC is set to AGC ON (see section 2.11)
h. Reticle mode is set to ARC (see section 2.20)
i. CAL is set to AUTO CAL ON (see section 2.19)
Note that reticle type and reticle adjustment settings
(EL/WND) are not changed during system reset.