EOTech Target Pointer Illuminator Aiming Light User Manual
Page 86

3-4
3.2 TROUBLESHOOTING PROCEDURES
The procedures below will help the operator correct some of
the basic problems that may arise with the AN/PEQ-2A. If
the equipment malfunction is not listed, or the actions listed
do not correct the fault, refer to Section II for additional
guidance.
a. Laser(s) fail to come on when activated.
(1) Verify Mode Selector is not in Position 0 (O).
(2) Verify that the battery is properly installed per
paragraph 2.2.2.
(3) Ensure that the Lens Caps and laser ports are
not obscured by mud or dirt.
(4) Replace existing battery with fresh battery.
b. Laser(s) appear weak.
(1) Ensure that the Lens Caps and laser ports are
not obscured by mud or dirt.
(2) Replace existing battery with fresh battery.
(3) Ensure Neutral Density Lens Cap, Pattern
Generator and/or Illuminator Diffuser Lens Cap
are not installed in front of laser ports.
(4) Check to see if the laser ports are scratched or
pitted.
3.3 CORRECTIVE MAINTENANCE
The AN/PEQ-2A has no internal parts or assemblies
replaceable at the operator level.
a. Replacement of Battery Cap Lanyard. No supplies
or tools are required to perform this procedure.
(1) Remove
Battery
Cap.
(2) Pull lanyard over Battery Compartment threads.