ii
3. SAFETY PRECAUTIONS
The following general safety precautions supplement the
specific WARNINGs, CAUTIONs and NOTEs that appear
elsewhere in this manual.
3.1 Laser Radiation. The AN/PEQ-2A employs invisible
laser radiation in the form of Infrared (IR) Aim and
Illumination Lasers. Nominal Ocular Hazard Distances
(NOHD) for safe operation are listed in Table i-1. Exposure
to the AN/PEQ-2A’s IR lasers inside these NOHDs can
cause irreversible damage to the human eye.
Table i-1 Nominal Ocular Hazard Distances for Safe
Operation (NOHD)
Laser/Mode Safety
Class
NOHD
w/o
1
NOHD
mag
2
OD
3
Unaided
OD
4
Aided
Infrared (IR)
Aim Low
1 0 0 - -
Infrared (IR)
Illuminator
Laser Low
3R 11 85
0.30
0.54
Infrared (IR)
Aim Laser
High
3B 218
1300
1.58 1.45
Infrared (IR)
Illuminator
Laser High
3B 55 331
1.41
1.65
1
Nominal Ocular Hazard Distance without magnifying optics (in meters)
2
Nominal Ocular Hazard Distance with 7x magnifying optics (in meters)
3
Necessary Optical Density (OD) at 10cm
4
Necessary Optical Density (OD) at 2m