beautypg.com

Gps 4100, Ag leader technology, General instructions – Ag Leader GPS 4100 Operators Manual User Manual

Page 15

background image

GPS 4100

General Instructions

Ag Leader Technology

March 2001

13

If you will
be using
RACAL…

Then…

Before contacting RACAL you must have the Receiver
Serial Number (Found on the Add-On GPS Diagnostic
screen – Press DIAG key, GPS key, Add-On GPS key) and
the Provider User Code (this value will appear on screen
shown on Figure 6 when Differential Provider is set to
RACAL). Call the RACAL subscription number (1-888-
434-7757 in the USA) and give them these two numbers.
RACAL will activate a code for the serial number that was
given. After the serial number is called in, press the EXIT
key (Figure 12) to return to operating screen. A "D"
should appear in the upper right hand corner of the
PF3000. Within 15 to 30 minutes the receiver should start
receiving corrections from RACAL.

SATELLITE DIFFERENTIAL SETUP

Differential Source

Satellite

Differential Provider

RACAL

Satellite Frequency

1553.345000

Satellite Baud Rate

1200

Provider User Code

8111

OMNISTAR Code 000000000000000000000000

ACCEPT

EXIT



Figure 12.