of HP SIM to test that events appear in HP SIM in the Event list or All Event User Interface
for the selected system.

.

You can also send test WBEM indications from some HP-UX version by running the following
procedure:

Procedure 7-1 Sending WBEM indications From an HP-UX system

1.

From the HP-UX managed system, run /ect/opt/resmon/lbin/send_test_event
monitor name

. For example, /etc/opt/resmon/lbin/send_test_event disk_em.

Possible monitor names:

dm_memory

lpmc_em

disk_em

dm_chassis

dm_core_hw

ia64_corehw

fpl_em

2.

Confirm that the test indication is shown in the HP SIM event table view after you trigger it.

Procedure 7-2 Sending WBEM indications from a Windows system

1.

Login to the target Windows system.

2.

Go to Start

ProgramsHP Insight WBEM ProvidersTest WMI events.

3.

Click any one of the severities (Informational, Warning, or Error).

4.

Click OK to send the test events to the CMS.

Procedure 7-3 Sending SNMP traps from Windows or HP-UX system

1.

Run Configure or Repair Agents and on Step 4: Configure or Repair Agents under
Configure

, select Send a sample SNMP trap to this instance of HP SIM to test that

events appear in HP SIM in the Event list or All Event User Interface for the selected
system.

2.

Confirm that the test trap is shown in the HP SIM event table view after you trigger it.

50