Table 32 RAID Manager error codes for Continuous Access Synchronous (SSB1 is
B901/B90A/B90B/B912/D004) (continued)
Description
Error code
(SSB2)
The pair cannot be created because the S-VOL is not implemented or is blocked (DEV NOT READY status).
C33E
The corresponding volume cannot be specified as an S-VOL because the volume is already specified as
Continuous Access Synchronous pair volume.
C33F
The P-VOL is not accessible.
C35C
The number of paths is fewer than the required minimum number following a path failure or because an
invalid path was specified.
C370
The process which is performed after the copying process of Auto LUN in the S-VOL is in progress. Retry
the operation several minutes later.
C371
The process which is performed after the copying process of Auto LUN in the P-VOL is in progress. Retry the
operation several minutes later.
C372
A request for a Paircreate operation was received. The command was rejected because the specified S-VOL
is a Business Copy Reserved volume.
C373
A request for a Paircreate operation was received. The command was rejected because the specified P-VOL
is a Business Copy Reserved volume.
C374
The number of paths is fewer than the required number of minimum following a path failure or because an
invalid path was specified.
C379
The S-VOL cache is unavailable.
C37E
The S-VOL DFW is disabled.
C37F
The primary system cache is in transition to blockage on one side.
C380
The primary system cache is in the process of being restored.
C381
The primary system cache is either in transition to blockage on one side or in the process of being restored
on one side.
C382
The secondary system is already used by Continuous Access Synchronous.
C38B
The S-VOL is not supported by Continuous Access Synchronous.
C38E
The S-VOL status is not PSUS or PSUE.
C390
The S-VOL cannot be copied to because it is in the wrong pair status.
C391
The S-VOL includes PIN data.
C393
The S-VOL cannot be used due to LDEV blockage, collection access, or other reasons.
C395
The pair cannot be created because the capacity of the P-VOL exceeded the maximum volume capacity
which is allowed to create a Continuous Access Synchronous pair.
C39E
The pair cannot be created because the capacity of the S-VOL exceeded the maximum volume capacity
which is allowed to create a Continuous Access Synchronous pair.
C39F
The P-VOL is a device not supported by Continuous Access Synchronous.
C3A0
The SSID or CU number of the secondary system is invalid.
C3A6
The secondary system’s cache is blocked on one side.
C3AA
The secondary system’s cache is blocked on one side.
C3AB
The secondary system capacity exceeds the license capacity.
C3AD
Continuous Access Synchronous is not installed on the secondary system.
C3AE
The DKC type of the secondary system is not supported by Continuous Access Synchronous.
C3AF