HP XP P9500 Storage User Manual
Page 79
Table 32 RAID Manager error codes for Continuous Access Synchronous (SSB1 is
B901/B90A/B90B/B912/D004) (continued)
Description
Error code
(SSB2)
The P-VOL is in process of drive copy for failure assistance.
C316
The P-VOL is in process of drive copy for an SVP request.
C317
The P-VOL is terminating the copy task.
C318
The P-VOL is in process of collection copy.
C319
The P-VOL is in process of collection access.
C31A
The P-VOL is blocked.
C31B
The P-VOL is blocked and impossible to access.
C31C
The P-VOL is being formatted.
C31D
The P-VOL is read only.
C31E
The number of primary-secondary system logical paths is 0 (for example, not specified).
C320
The number of primary-secondary system logical paths is smaller than the minimum required.
C321
The DKC type of the primary system does not support Continuous Access Synchronous.
C322
The secondary system’s sequence number, SSID, or CU are invalid.
C324
The pair cannot be created because the P-VOL is not available for remote copy.
C327
The track formats of the P-VOL and the S-VOL do not match.
C328
The S-VOL is protected by the Data Retention.
C32A
The P-VOL is protected by the Data Retention.
C32B
The S-VOL is protected by the Data Retention.
C32C
A request for a Paircreate operation was received. The command was rejected because the specified
secondary system is an unsupported product.
C32E
The number of P-VOL cylinders is not the same or smaller than the number of S-VOL cylinders.
C32F
The P-VOL's volume capacity is not equal to the S-VOL’s.
C330
S-VOL cache is unavailable.
C332
S-VOL DFW is disabled.
C333
The S-VOL is the P-VOL of Continuous Access Synchronous.
C335
The S-VOL includes PIN data.
C336
The S-VOL is in reserve status.
C337
Copy pair cannot be created because of the either of the following reasons.
C338
•
The S-VOL is in the intervention-required condition, protected, or unusable status.
•
The S-VOL is the S-VOL or Reserved volume of Business Copy, Reserved volume of Auto LUN, or the
volume of Continuous Access Journal pair.
A request for a Paircreate operation was received. The command was rejected because the secondary
system is a not supported by Continuous Access Synchronous.
C33A
The corresponding volume cannot be specified as an S-VOL because the volume is used as another pair’s
S-VOL.
C33B
A request for a Paircreate operation was received. The command was rejected because the specified S-VOL
was not mounted.
C33C
Troubleshooting using RAID Manager
79