Thin provisioning z – HP XP P9500 Storage User Manual
Page 38
Table 18 Status, availability of DRU operation (continued)
Referencing access attribute
Changing access attribute
Pair status
Continuous
Access
Synchronous
volume
Yes
Yes
PSUS
Yes
Yes
PSUE
Yes
Yes
SMPL
S-VOL
Yes
No
COPY
Yes
No
PAIR
Yes
No*
PSUS
Yes
No
PSUE
* If the S-VOL Write option is enabled, the access attribute can be changed.
The following table indicates whether a DRU volume with the specified access attribute can be
used as a Continuous Access Synchronous P-VOL or S-VOL.
Table 19 DRU access attribute with Continuous Access Synchronous P-VOL/S-VOL
Availability for Continuous Access Synchronous P-VOL or S-VOL
DRU access attribute
S-VOL
P-VOL
Read/Write
Yes
Yes
Yes
Yes
Read Only
Yes
Yes
Protect
No
Yes
S-VOL Disable
No
Yes
Read Only and S-VOL Disable
No
Yes
Protect and S-VOL Disable
Thin Provisioning Z
The virtual volume of Thin Provisioning Z (V-VOL) can be assigned as a part of Cnt Ac-S Z pair. A
Cnt Ac-S Z pair creation with a V-VOL and a not-V-VOL is also available. See the following table
for the details.
Table 20 Cnt Ac-S Z pair availability with V-VOL and not-V-VOL
S-VOL
P-VOL
( Device emulation type )
( Device emulation type )
not-V-VOL ( 3390-X
*1
)
not-V-VOL ( 3390-A )
V-VOL ( 3390-A )
Not available
Available
Available
V-VOL ( 3390-A )
Not available
Available
Available
not-V-VOL ( 3390-A )
Available
Available
Available
not-V-VOL ( 3390-X
*1
)
*1
The 3390-X above represents the device emulation types of 3390 series except 3390-A. (see
for the 3390 device emulation types supported by Cnt Ac-S Z.) The V-VOL
combined with the device types other than 3390 is not available.
To enable the data migration from existing storage to the V-VOL (3390-A) or not-V-VOL (3390-A),
a combination of the not-V-VOL (3390-X) as the P-VOL and the V-VOL (3390-A) or not-V-VOL
38
Sharing Continuous Access Synchronous volumes