beautypg.com

HP XP P9500 Storage User Manual

Page 78

background image

Table 32 RAID Manager error codes for Continuous Access Synchronous (SSB1 is

B901/B90A/B90B/B912/D004) (continued)

Description

Error code

(SSB2)

The command was rejected because the S-VOL status is SMPL.

C233

The command was rejected because an internal logical error has occurred.

C234/C235/
C236/C237

The command was rejected because the specified volume is the volume other than P-VOL.

C238

The command was rejected because the pair resync was operated to the volume which status is other than
PSUS, PSUE, or PDUB.

C239

The command was rejected because an internal logical error has occurred.

C23A

The command was rejected because the volume status is SMPL.

C23B

The command was rejected because the volume status is other than PAIR or COPY.

C23C

The command was rejected because the command for Continuous Access Synchronous synchronous was
issued to the Continuous Access asynchronous volume.

C23D

The pair cannot be created because the command was issued to the command device.

C267

The command was rejected because the specified consistency group number is invalid.

C271

The command was rejected because the takeover command was issued to a volume whose status is not
SSWS.

C28B

The command was rejected because the secondary system is not registered or the registered information is
invalid.

C28C

There is no volume to which the takeover command can be executed.

C28D

The command was rejected because an internal logical error has occurred.

C28E

The command was rejected because the specified volume is used as an S-VOL.

C297

The pair cannot be created because the capacity that is used by program products other than Continuous
Access Synchronous exceeds license capacity.

C2A0

The command was rejected because an internal logical error has occurred.

C2A1

The pair cannot be created because the used capacity exceeds the license capacity.

C2A3

The pair cannot be created because the used capacity exceeds the license capacity.

C2A4

The command was rejected because V-VOL capacity is changing.

C2B3

The command was rejected because an internal logical error has occurred.

C2B4

The pair cannot be created because the Continuous Access Synchronous P-VOL is being initialized by
Business Copy.

C2B5

The command was rejected because the releasing pages in V-VOL is in progress.

C2B6

A request for a Paircreate operation was received. The command was rejected because the capacity that
is used by Continuous Access Synchronous in the secondary system exceeds license capacity. Check license
capacity, including for related program products.

C305

The volume in the secondary system or another volume that belongs to the same group is changing to Simplex
or Suspend status. Retry the operation after several minutes.

C30D

The P-VOL is not in SMPL status.

C312

The P-VOL is not in PSUS status.

C313

The P-VOL is not in SMPL status.

C314

The P-VOL includes PIN data.

C315

78

Troubleshooting