HP XP P9500 Storage User Manual
Page 78
Table 32 RAID Manager error codes for Continuous Access Synchronous (SSB1 is
B901/B90A/B90B/B912/D004) (continued)
Description
Error code
(SSB2)
The command was rejected because the S-VOL status is SMPL.
C233
The command was rejected because an internal logical error has occurred.
C234/C235/
C236/C237
The command was rejected because the specified volume is the volume other than P-VOL.
C238
The command was rejected because the pair resync was operated to the volume which status is other than
PSUS, PSUE, or PDUB.
C239
The command was rejected because an internal logical error has occurred.
C23A
The command was rejected because the volume status is SMPL.
C23B
The command was rejected because the volume status is other than PAIR or COPY.
C23C
The command was rejected because the command for Continuous Access Synchronous synchronous was
issued to the Continuous Access asynchronous volume.
C23D
The pair cannot be created because the command was issued to the command device.
C267
The command was rejected because the specified consistency group number is invalid.
C271
The command was rejected because the takeover command was issued to a volume whose status is not
SSWS.
C28B
The command was rejected because the secondary system is not registered or the registered information is
invalid.
C28C
There is no volume to which the takeover command can be executed.
C28D
The command was rejected because an internal logical error has occurred.
C28E
The command was rejected because the specified volume is used as an S-VOL.
C297
The pair cannot be created because the capacity that is used by program products other than Continuous
Access Synchronous exceeds license capacity.
C2A0
The command was rejected because an internal logical error has occurred.
C2A1
The pair cannot be created because the used capacity exceeds the license capacity.
C2A3
The pair cannot be created because the used capacity exceeds the license capacity.
C2A4
The command was rejected because V-VOL capacity is changing.
C2B3
The command was rejected because an internal logical error has occurred.
C2B4
The pair cannot be created because the Continuous Access Synchronous P-VOL is being initialized by
Business Copy.
C2B5
The command was rejected because the releasing pages in V-VOL is in progress.
C2B6
A request for a Paircreate operation was received. The command was rejected because the capacity that
is used by Continuous Access Synchronous in the secondary system exceeds license capacity. Check license
capacity, including for related program products.
C305
The volume in the secondary system or another volume that belongs to the same group is changing to Simplex
or Suspend status. Retry the operation after several minutes.
C30D
The P-VOL is not in SMPL status.
C312
The P-VOL is not in PSUS status.
C313
The P-VOL is not in SMPL status.
C314
The P-VOL includes PIN data.
C315
78
Troubleshooting