HP XP P9500 Storage User Manual
Page 13
Table 4 Status of Cnt Ac-S pairs and Cnt Ac-S Z pairs and the result when the pair splitting operation
is performed (RAID Manager (RM))
Cnt Ac-S Z pairs
Pair Status
All pairs are in Suspend
status
There are pairs in both
Duplex status and
Suspend status
All pairs are in Duplex
status
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
All pairs are in PAIR
status
Cnt Ac-S
pairs
Cnt Ac-S Z pairs : Suspend
Cnt Ac-S Z pairs :
Suspend
Cnt Ac-S Z pairs :
Suspend
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
There are pairs in
both PAIR status
and PSUS status
Cnt Ac-S Z pairs : Suspend
Cnt Ac-S Z pairs :
Suspend
Cnt Ac-S Z pairs :
Suspend
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
All pairs are in
PSUS status
Cnt Ac-S Z pairs : Suspend
Cnt Ac-S Z pairs :
Duplex/Suspend
Cnt Ac-S Z pairs : Duplex
Table 5 Status of Cnt Ac-S pairs and Cnt Ac-S Z pairs and the result when the pair splitting operation
is performed (Business Continuity Manager)
Cnt Ac-S Z pairs
Pair Status
All pairs are in Suspend
status
There are pairs in both
Duplex status and Suspend
status
All pairs are in Duplex
status
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
All pairs are in
PAIR status
Cnt Ac-S
pairs
Cnt Ac-S Z pairs :
Suspend
Cnt Ac-S Z pairs : Suspend
Cnt Ac-S Z pairs : Suspend
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
There are pairs in
both Pair status
and PSUS status
Cnt Ac-S Z pairs :
Suspend
Cnt Ac-S Z pairs : Suspend
Cnt Ac-S Z pairs : Suspend
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
Cnt Ac-S pairs : PSUS
All pairs are in
PSUS status
Cnt Ac-S Z pairs :
Suspend
Cnt Ac-S Z pairs : Suspend
Cnt Ac-S Z pairs : Suspend
To define or operate the Cnt Ac-S Z pairs in the consistency groups, install the Continuous Access
Synchronous operations can be performed on pairs inZ software. A Continuous Access Synchronous
consistency group and a maximum of 128Continuous Access Synchronous Open/MF consistency
groups ongroup described in the primary system.HP P9000 Continuous Access Synchronous for
Mainframe Systems User Guide are the same. For further information on a Continuous Access
Synchronous Open/MF consistency group, see the HP P9000 Continuous Access Synchronous for
Mainframe Systems User Guide.
You must use the same consistency group number when Cnt Ac-S pairs and Cnt Ac-S Z pairs are
registered in the same Continuous Access Synchronous consistency group. Therefore, you must
decide beforehand the consistency group number by both RAID Manager (RM) and Business
Continuity Manager. Specify the unused consistency group number. Before you start the operation,
define the pair specifying the consistency group number with RAID Manager (RM) and Copy Group
Attributes (TC) window of Business Continuity Manager. For further information about the Copy
Group Attributes (TC) window, see the HP P9000 Business Continuity Manager User Guide.
Consistency groups
13