Table 32 RAID Manager error codes for Continuous Access Synchronous (SSB1 is
B901/B90A/B90B/B912/D004) (continued)
Description
Error code
(SSB2)
The command was rejected because the volume status is SMPL.
B97C
The pair cannot be created because the consistency group number is greater than is allowed.
B990
If this error occurred when you did not specify the consistency group number, contact HP Technical Support.
The Swap Resync operation cannot be performed because the S-VOL is not in PSUS or SSWS status (Swap
Resync resynchronizes differential data when the S-VOL is swapped for the P-VOL).
B994
The pair cannot be created because the remote system path setting in Remote Web Console is invalid.
B998
The pair cannot be created because Continuous Access Asynchronous is not supported.
B99B
The DKC LDEV configuration might have been changed while starting RAID Manager. Restart RAID Manager.
B9BD
The source of the command device has run out. In LUN Manager, set the command device to OFF, then to
ON.
B9C0
A request for a Pairresync operation was received. The command was rejected because the pair was not
in the Suspend status.
C162
A request for a Pairsplit-S operation was received. The command was rejected because the status change
of the S-VOL failed.
C184
A request for a Pairsplit-S operation was received. The command was rejected because the pair status was
invalid.
C189
A request for a Pairsplit-S operation was received. The command was rejected because the corresponding
volume or group was changing status.
C18A
The pair cannot be split because the S-VOL pair status was in transition.
C194
A request for a Pairsplit-r operation was received. The command was rejected because the pair status was
already PSUS or PSUE.
C195
Pair split cannot be executed because the group includes no pair that can be split.
C198
A request for a Pairsplit-r operation was received. The command was rejected because the corresponding
volume or group was changing status.
C199
The pair’s status cannot be changed during the power-on processing of the DKC.
C1BE
The command was rejected because the specified volume is used for a P-VOL.
C211
The command was rejected because the specified volume is used for an S-VOL.
C212
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C214
The command was rejected because an internal logical error has occurred.
C215
The command was rejected because the pair status is invalid.
C218
The command was rejected because the P-VOL status is not PSUS, PSUE, or PDUB.
C21A
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C21C
The command was rejected because the pair release is executed to the volume other than P-VOL.
C22A
The command was rejected because the volume status is SMPL.
C22C
The command was rejected because the specified volume is the volume other than the P-VOL.
C22D
The command was rejected because the pairsplit command specifying -P option (write protection of P-VOL)
was issued to a volume whose status is not PAIR.
C22E
Troubleshooting using RAID Manager
77