HP XP P9500 Storage User Manual
Page 59
Table 20 RAID Manager Error Codes (continued)
Description
SSB2 code
The pair operation was rejected because the current microcode version does not support the specified
secondary volume capacity.
2048
The volume specified as a primary volume was a volume of a Cnt Ac-J pair. The pair operation was
rejected because the status of the Cnt Ac-J pair was invalid.
2060
The volume specified as an secondary volume was a volume of a Cnt Ac-J pair. The pair operation
was rejected because the status of the Cnt Ac-J pair was invalid.
2061
Volumes of the specified pair were shared by Cnt Ac-S and Cnt Ac-J. The quick restore or reverse
copy operation was rejected because the status of the Cnt Ac-S or Cnt Ac-J pair was not PSUS.
2067
The pair operation was rejected because the specified primary or secondary volume was being
shredded.
2068
The pair operation was rejected for one of the following reasons:
2072
•
The primary volume was also a Snapshot pool volume.
•
The primary volume was also a Snapshot secondary volume (V-VOL).
•
The primary volume was also a Snapshot primary volume, and one of the following conditions
was also true.
- While the Snapshot pair was restored, the create, split, or resync pair operation was performed
on the BC pair.
- The BC quick restore operation was performed.
- A consistency group was defined for BC.
- After the MU number used by a Snapshot pair was specified, the create, split, or resync pair
operation was performed on the BC pair.
The pair operation was rejected for one of the following reasons:
2073
•
The secondary volume was also a Snapshot pool volume.
•
The secondary volume was also a Snapshot secondary volume (V-VOL).
•
The secondary volume was a Snapshot secondary volume pair, and one of the following conditions
was also true.
- The Snapshot pair was being restored.
- The BC quick restore operation was performed.
- A create pair operation was performed on the BC pair.
Because the specified primary volume was also a Cnt Ac-J P-VOL for delta resync, one of the following
errors occurred.
2078
•
The reverse copy operation was rejected because the Cnt Ac-J pair was not in the PSUS status.
•
The quick restore operation was rejected.
The pair operation was rejected because the specified primary volume was also a Cnt Ac-J P-VOL for
delta resync.
2079
The pair operation was rejected because the initialization process was being performed.
2086
The quick restore operation was rejected because the volume specified as a primary volume was
undergoing quick format
2089
The quick restore operation was rejected because the volume specified as an secondary volume was
undergoing quick format.
208a
The volume specified as a primary volume was a Cnt Ac-S S-VOL. The split operation was rejected
because the status of the Cnt Ac-S pair was not Suspend.
2093
The volume specified as a primary volume was a Cnt Ac-S S-VOL. The Split operation was rejected
because the consistency time of the consistency group is not equal to the consistency time of the Cnt
Ac-S pair.
2094
Troubleshooting with RAID Manager
59