beautypg.com

2 zone group concepts and device mappings, Zone group concepts, Device mappings – HP 6Gb SAS Switch for HP BladeSystem c-Class User Manual

Page 9: Zone group concepts device mappings

background image

2 Zone group concepts and device mappings

Zone group concepts

Zone groups allocate resources for device load balancing purposes and for selectively allowing
access to data. For planning purposes, zone groups and assignments can be pre-configured, even
if servers or disk drives are not yet installed.

Types of zone groups:

Switch port zone groups—Group together one or more ports on the SAS BL Switch. Server
device bays assigned this type of zone group have access to the storage enclosures or tape
devices connected to the ports included in the zone. This type of zone group is for shared
SAS devices. The P2000 G3 SAS MSA and HP MSL2024, MSL4048, and MSL8096 Tape
Libraries and 1/8 G2 Tape Autoloader are examples of shared SAS devices. All LUNs in the
controller enclosure are accessible to the assigned servers, unless controlled through the storage
management utility for the controller enclosure and all tape drives in a tape device are
accessible to any server that has access to the zone group.

Drive bay zone groups—Group together drive bays from one or more MDS600 drawers or
D2000 disk enclosures. Server device bays assigned this type of zone group have exclusive
access to the drive bays included in the zone group, as if the drives are directly connected to
those servers. This type of zone group is for zoned SAS storage enclosures. The MDS600 and
D2600/D2700 enclosures are examples of zoned SAS storage.

As shown in the following table, configuration (zoning type) procedures are the same for shared
SAS storage enclosures and tape devices, but differ for zoned SAS storage enclosures:

Zoning type

Type of connected external device

Switch port

Shared SAS storage enclosures (P2000 G3 SAS MSA)

Drive bay

Zoned SAS storage enclosures (MDS600 and D2600/D2700)

Switch port

Tape devices

Device mappings

IMPORTANT:

Depending on the BladeSystem c-Class enclosure model, server type, mezzanine

slot used, and BladeSystem server device bay, the SAS BL Switch must be installed in specific
BladeSystem interconnect bay row. The following tables show the interdependencies of components
in an HP BladeSystem c-Class solution that includes SAS BL Switch connected to external SAS
storage enclosures.

Device mappings for the c3000 BladeSystem enclosure:

BladeSystem c-Class

nl

interconnect bay

Mezzanine slot

Server type

BladeSystem c-Class

nl

enclosure model

3/4

2

Half height

c3000

2

Full height

3

2

Full height

nl

Double wide

nl

3

(BL680c G7)

4

7

Zone group concepts

9