background image

Assigning a zone group to a server device bay

Server device bays cannot access external storage connected to the switch until assigned a zone
group.

IMPORTANT:

For an existing zone group, when changing the assignment to move the zone group to a
different server device bay, you must first stop all associated I/O with the zone group and
power off the server blades. After completing the assignments and saving all changes in the
VSM, restart the servers and resume I/O.

Syntax

add

[zg=]

Parameters

The exact name of the zone group to assign to the target blade
bay.

zg=

NOTE:

The following example demonstrates assigning a switch-port zone group to a server.

When assigning a drive-bay zone group to a server, the display differs, but underlying principles
remain the same.

1.

[Optional] Verify the status of the enclosure server device bays. Use the show command to
display all configured zone groups.

As shown in this example, information for the zone group, Ports_1, created in

“Creating a

switch-port zone group” (page 65)

, and information for the zone group created in

“Creating

a drive-bay zone group” (page 67)

is displayed. As shown, Ports_1 and zone5 have not yet

been assigned to a server.

=> switch loc=local zg all show detail

Blade Enclosure At BottomC7000
Switch: Local (VSM Active)
Zone Group: Ports_1 (Unassigned)
Zoned Blade Switch Port: 54
Zoned Blade Switch Port: 64
Storage Connection Status: Online
Overall Status: OK
Zone Group: zone5 (Unassigned)
Connected Expander: Expander 1
Zoned Storage Enclosure Bay: 51:1:29 - Occupied
Zoned Storage Enclosure Bay: 51:1:30 - Occupied
Zoned Storage Enclosure Bay: 51:1:31 - Empty
Zoned Storage Enclosure Bay: 51:1:32 - Empty
Zoned Storage Enclosure Bay: 51:1:33 - Occupied
Zoned Storage Enclosure Bay: 51:1:34 - Occupied
Zoned Storage Enclosure Bay: 51:1:35 - Occupied
Storage Connection Status: Online
Overall Status: OK

2.

Assign the zone group to the server device bay.

This example shows how to assign the zone group “Ports_1” created in

“Creating a switch-port

zone group” (page 65)

to BladeSystem device server bay 1.

=> switch loc=local startupdate
Success

=> bladeport id=1 add zg=Ports_1
Success

=> switch loc=local saveupdate

Assigning a zone group to a server device bay

69