beautypg.com

The show command – HP 6Gb SAS Switch for HP BladeSystem c-Class User Manual

Page 60

background image

The show command

The show command displays information about a device. Use this command to view the current
status of a device and its configuration.

Syntax

show

[config] [detail]

Parameters

Forces the display to include configuration information about the
specified target device.

config

detail

Forces a more detailed display, including information for other items
such as zone groups.

Example 1: The following example displays the results of the show command for a blade enclosure.

=> bladeenclosure local show

Blade Enclosure at R20_top
Rack Name: R20
Version: 1.00
Blade Bay Count: 16
Fan Bay Count: 10
Power Supply Bay Count: 6
Thermal Sensor Count: 3
Interconnect Bay Count: 8
OA Bay Count: 2
Serial Number: USE104690F
Status: OK

Example 2: The following example displays the results of the show command for a blade enclosure
device bay.

=> bladeport id=1 show

Blade Enclosure at R20_top
Blade Port: 1 (ProLiant BL460c G6)
Zone Groups: Ports_1
Blade: ProLiant BL460c G6(SN: MXQ93100UL)
Type: Server Blade
Manufacturer: HP
Part Number: 507784-B21
Serial Number: MXQ93100UL
ROM Version: I24 06/20/2009
CPU Count: 2
Memory [MB]: 6144
NIC Count: 5
Power: On

60