The show command – HP 6Gb SAS Switch for HP BladeSystem c-Class User Manual
Page 60

The show command
The show command displays information about a device. Use this command to view the current
status of a device and its configuration.
Syntax
[config] [detail]
Parameters
Forces the display to include configuration information about the
specified target device.
config
detail
Forces a more detailed display, including information for other items
such as zone groups.
Example 1: The following example displays the results of the show command for a blade enclosure.
=> bladeenclosure local show
Blade Enclosure at R20_top
Rack Name: R20
Version: 1.00
Blade Bay Count: 16
Fan Bay Count: 10
Power Supply Bay Count: 6
Thermal Sensor Count: 3
Interconnect Bay Count: 8
OA Bay Count: 2
Serial Number: USE104690F
Status: OK
Example 2: The following example displays the results of the show command for a blade enclosure
device bay.
=> bladeport id=1 show
Blade Enclosure at R20_top
Blade Port: 1 (ProLiant BL460c G6)
Zone Groups: Ports_1
Blade: ProLiant BL460c G6(SN: MXQ93100UL)
Type: Server Blade
Manufacturer: HP
Part Number: 507784-B21
Serial Number: MXQ93100UL
ROM Version: I24 06/20/2009
CPU Count: 2
Memory [MB]: 6144
NIC Count: 5
Power: On
60
Getting help
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)