NOTE:

Once a system is added, the system definition persists from session to session unless it

is removed.

In the Add System window, these fields define a Neoview system:

Your Name for System

— enter an alias name to identify this Neoview system. The name

can be up to 32 characters in length, and consist of letters, digits, and the underscore character.

Server Data Source

— enter the name of the data source on the Neoview system. If the

field is left blank, the default data source is used if it one has been configured.

User Name

— Neoview user name.

Password

— Neoview password.

Host

— enter the DNS name or IP address for the target Neoview platform.

Port Number

— contains the ODBC server port number.

Default Schema

— contains the default schema to use if composing a query (optional).

Driver

— enter the installed Neoview ODBC driver to be used with this Neoview system.

In the Add System window, these buttons allow you to test or add a new system, or close the
system definition.

[Test] verifies the validity of a new system using the entries specified in the fields of the Add
System
window. [Test] is enabled if one or more systems is selected. The selected system is
tested and the result is displayed in the Connection Test Result window. This action will:

Cause an attempt to make a connection to the Neoview system specified in the Add System
window.

Return the validating result in the Connection Test Result window that indicates the
following:
— Test succeeded – the settings have been tested and the system is added to the My

Active Systems folder. (Database area only)

— Test failed – the settings have been tested and the test failed. If the test failed, the

reason for the failure in also provided in the Connection Test Result window. The
system is added to the My Other Systems folder. (Database area only)

— Password not specified – the password has been specified. If the password is

empty, you must have clicked in this field to explicitly set an empty password. The
system is added to the My Other Systems folder. (Database area only)

— Not tested – the entry is possibly empty and has not been tested. The system is added

to the My Other Systems folder. (Database area only)

[OK] attempts to create the new system using the entries specified in the fields of the Add System
window. This action will:

Cause an attempt to make a connection to the Neoview system specified in the Add System
window.

If the connection is successful, the entry for the system is created and appears in the Systems
Tool
window.

If the connection attempt is not successful, a Connection Test Result window opens and
indicates the test failed for the Neoview system specified in the Add System window. Click
[OK] to close the Connection Test Result window.

14