6.1 Cabling

Limitations

Maximum total allowable cable length for a differential SCSI interface is 82 feet (25 meters). This distance
must be measured from the controller to the last device on the bus. Cables must be 110 ohm twisted pair. If

you are using a cable of unknown composition, replace it with the one provided by HP. When ordering,
reference one of these part numbers:


519-001W

424360-001

1 meter (3 foot) SCSI Cable 68-pin to 68-pin

519-003W

424361-001

3 meter (10 foot) SCSI Cable 68-pin to 68-pin

519-015W

424362-001

15 meter (50 foot) SCSI Cable 68-pin to 68-pin

519-020W

424917-001

20 meter (67 foot) SCSI Cable 68-pin to 68-pin

519-023W

424363-001

23 meter (77 foot) SCSI Cable 68-pin to 68-pin

6.2 Differential

Devices

The 5242 and 5242-ACL tape drives support a high voltage differential SCSI-3 interface.

6.3

Cooling Fan and System

The cooling system provides excellent heat dissipation at critical locations, such as read/write heads, where
excess heat results in higher data failure. A unique airflow design directs cool air over these critical locations

within the chassis.

6.4 Specifications

This section provides technical specifications for the tape drives.

6.4.1 Electrical

Specifications


6.4.1.1 External AC power:

• V115/230

1.0/0.5A 50/60

Hz

6.4.1.2 AC power outlet (to be used for stacking units only)

V115/ 230 7.0/3.5A

50/60 Hz

6.4.1.2 Internal DC power:

• 5242: +5, +12 volts 25 watts
• 5242-ACL: +5, +12 volts 65 watts

6.4.2 Display

Unit

32 characters in 4 lines of 8 characters each

Supertwist LCD technology

• Extra-wide

viewing

angle

Full LED back lighting