HP Integrity NonStop H-Series User Manual

Page 23

background image

Section 1: General Information

This report shows $TAPE0 is:

• Using

processor

0 as the primary processor

• Using

processor

1 as the backup processor

• Logical

device

68

• In

the

STARTED state

Currently online at BOT

A DDS-3 (5142) tape drive (5242 would be shown for that model)

For more on the STATUS command, refer to the SCF Reference Manual for the Storage

subsystem

3.2.5

Troubleshooting the 5242 and 5242-ACL Tape Drives

These troubleshooting tables help identify and correct problems that can occur when installing the
5242 or 5242-ACL tape drives. Each table addresses a specific problem, lists symptoms related to

the possible cause of the problem, and lists actions to correct problem. If you need further help
solving an installation problem, contact the HP Global Customer Support Center.

5242 Tape Drive Does Not Function Properly

Symptom Correct

Action

Tape drive does not respond

to software commands, or it

functions abnormally.


Note: Refer to page 32 to

identify error

conditions indicated

by drives status LEDs.

• Check that a SCSI cable is

firmly attached to one of

the SCSI ports on the back

of the tape drive.

• Use SCF commands to

isolate the problem in the

tape drive. See SCF

example commands on

page 19.

• Check that the SCSI ID is

set to 5.

• If SCSI bus termination

problems are suspected,
check the terminator on the

rear of the tape drive.

• If you cannot find the

problem, contact the

GCSC.

Table 8

Troubleshooting the 5242 Tape Drive

HP StorageWorks DAT 72 (Models 5242 and 5242-ACL) User's Guide

16 HP Part Number 528296-03 July 2005