Section 1: General Information

Note: If the cleaning cartridge ejects after 14 seconds. The cartridge has reached the end

of its useful life, and no cleaning has occurred. If the cleaning needed LED is still

illuminated, discard the cartridge and repeat the cleaning operation with a new
tape.


4.2.1.2 Remove the cleaning cartridge from the drive. Write the date on the label of the cleaning

cartridge so that you have a record of usage. Do not use the cleaning cartridge more times
than specified by the manufacturer.

4.3

5242-ACL Tape Path Cleaning

Clean the heads regularly. Do not use the cleaning cartridge for more than the manufacturer's specified

number of cleaning cycles. Always and immediately clean the heads when a Clean Me message appears on
the autoloader's LCD and when the Operator Attention LED flashes amber.

Programmable
Error-Alert LED

Compression
Indicator LED

Write
E F
COMPRESS
2.3:1

Eject

6

Mode
Switch

4-Line LCD,
8-Characters per line

Select Button

Eject

Button

Load

Tape

Button

Tape

Activity

LED

Operator

Attention
Required

LED

Magazine
Present
LED

Autoloader
LCD


Figure 21

5242-ACL front panel

Recommended Cleaning Schedule for

125m DDS-3 and 170m DAT72 Tape Cartridges

Number of

DDS cartridges
used each day

1 2 3

4

or

more

Recommended
Cleaning

Frequency

8 weeks

4 weeks

3 weeks

weekly

Table 11

5242-ACL cleaning schedule using DDS-3 or DAT72 cartridges

4.3.1 Cleaning

the

Heads:


4.3.1.1 Place the cleaning cartridge into the first magazine slot. Insert the magazine into the

autoloader. The tape loads automatically into the drive.

4.3.1.2 At the end of the cleaning cycle, the drive automatically ejects the cartridge. The changer

mechanism places it in the magazine.