Section 1: General Information
• 5242-ACL
dimensions
•L292mm x W211mm x H107mm
•L11.5" x W8.3" x H4.2"
•
The AC power cord measures 1.8 meters (6 feet).
•
The maximum cable length for attaching a 5242 or 5242-ACL to a NonStop S-series
server, M8201 Fibre Channel to HVD SCSI router, or NonStop S-series I/O enclosure
is 25 meters (82 feet).
3.2.1.3 Environmental
Requirements
Factor
Operating (with
tape loaded)
Nonoperating
Temperature
5ºC to 40ºC
-40ºC to 45ºC
Relative
Humidity
20% to 80%
5% to 95%
Acoustic Noise
28 dB
N/A
Table 5
Environmental requirements for the 5242 and 5242-ACL
Country/
Region
Current
(Amps)
Voltage
(Volts)
Plug
North America
(locking plug)
10 125
NEMA
5-15P
North America
(locking
receptacle)
10 125
NEMA
5-15R
Austria,
Belgium,
Finland, France,
Germany,
Netherlands,
Norway and
Sweden
10 250
CEE
7/7
Australia, New
Zealand
10 250
AS
3112
United Kingdom
10
250
BS-1363
Switzerland 10
250
SEV
1011.1959
Italy 10
250
CEI
23-16/VII
Denmark 10
250
Afsnit
107
Table 6
Current and voltage ratings of AC power cords available for the tape drive
HP StorageWorks DAT 72 (Models 5242 and 5242-ACL) User's Guide
7 HP Part Number 528296-03 July 2005