30 the syslog window – HP XP20000XP24000 Disk Array User Manual
Page 66
Figure 30 The Syslog Window
The Syslog window has the following features:
•
Output to Primary Server: You can specify whether to transfer the audit log to the primary syslog
server. To transfer the audit log to the primary syslog server, select Enable. If you do not want to
transfer the audit log to the primary syslog server, select Disable.
•
Primary Server Setting: You can set IP Address and Port Number for the syslog server that you
want to set as the primary syslog server. As you set Output to Primary Server to Enable, IP
Address and Port Number become available. For both IP Address and Port Number, the defaults
have been entered, so change them as you need. For IP Address, you need to enter four integral
numbers in the range of 0 to 255 (for example, nnn.nnn.nnn.nnn, where n is a numeric).
You need to enter only numbers, and not the periods. For Port Number, you need to enter an
integral number in the range of 1 to 65,535.
•
Output to Secondary Server: You can specify whether to transfer the audit log to the secondary
syslog server. To transfer the audit log to the secondary syslog server, select Enable. If you do not
want to transfer the audit log to the secondary syslog server, select Disable.
•
Secondary Server Setting: You can set IP Address and Port Number for the syslog server that you
want to set as the secondary syslog server. As you set Output to Secondary Server to Enable, IP
Address and Port Number become available. For both IP Address and Port Number, the defaults
have been entered, so change them as you need. The restriction for the available values is
the same as that of Primary Server Setting.
•
Location Identification Name: You can name the storage system that transfers the audit log to
syslog servers, so that you can identify the storage system. You can enter 32 one-byte characters
at the maximum. Available characters are alphabetic (A-Z and a-z), numeric (0-9), and symbols
(including ! " # $ % & ' ( ) = - ~ ^ | \ { } [ ] @ ‘ : ; * + _ ? / < > .). However, a comma (,) and
a space cannot be used.
•
Output Detailed Information: You can set whether to transfer the detailed information for the audit
log information file to the syslog server. To transfer the detailed information to the syslog server,
select Enable. If you do not, select Disable.
66
Using the Remote Web Console GUI