Server-port-map – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 50

Command line 50
Item
Description
Displays detailed information for all physical server ports
->show server-port enc0:3:d2
Displays detailed information for a specific server port
server-port-map
Manage shared server downlink port mapping configuration
Supported actions: add, help, remove, set, show
Item
Description
add server-port-map Add a new server port network mapping, and allow server ports to be shared
among multiple VC Ethernet networks.
This command cannot be used if the domain setting VLanTagControl is currently set
to "Tunnel".
Syntax
add server-port-map
[Uplinkset=
[Untagged=
Parameters
ConnectionID
(required)
The reference ID of an existing enet-connection associated with a profile and a
server port. The format of the ConnectionId is
Network (required) The name of a valid network to which the mapping will be added. A network can
be configured once for every profile connection, and every profile connection can
be configured for a maximum of 28 networks.
Properties
Uplinkset (optional) The name of the shared uplinkset to use with the server port mapping. If the domain
setting SharedServerVLanId is set to "true", then the Uplinkset is a required value.
VLanID (optional)
The VLAN ID to be used for the mapping. Valid values include 1 to 4094. If the
uplinkset name is specified, then the VLanID property should not be specified,
because the server VLAN ID is forced to be same as the VLAN ID used when adding
the network to the shared uplinkset.
Untagged (optional) Enables or disables the network to handle untagged packets. Only one network in
an Ethernet network connection can be made to handle untagged packets. The
default value is "false". If a shared uplink set is being used, then the untagged
network is the same as the native network, if present, but any other network can be
configured to handle untagged packets.
Examples
->add server-port-map MyProfile:1 Network1 VLanID=100
Adds a new server port to dedicated network mapping
->add server-port-map MyProfile:2 RedNetwork
Uplinkset=MyUplinkSet1
Adds a new server port to shared network mapping
->add server-port-map MyProfile:3 GreenNetwork
Uplinkset=MyUplinkset1 UnTagged=true
Adds a new server port to shared network and label it as untagged
Item
Description
remove
server-port-map
Remove a server port network mapping. This command cannot be used if the
domain setting VLanTagControl is set to "Tunnel".
Syntax
remove server-port-map
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem