HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 61

Command line 61
Item
Description
Examples
->add uplinkport enc0:1:1 Network=MyNetwork
Adds a new uplink port (Bay 1, Port 1) to a network
->add uplinkport enc0:2:4 Network=MyNetwork Speed=1Gb
Adds a new uplink port (Bay 2, Port 4) to a network and sets the port speed
->add uplinkport enc0:2:3 UplinkSet=MyUplinkSet
Adds a new uplink port (Bay 2, Port 3) to a shared uplink port set
->add uplinkport enc0:2:4 Network=MyNetwork Role=Primary
Adds a new uplink port to a network with the connection mode as Failover and the port
role as Primary
Item
Description
remove uplinkport Remove an uplink port element from a network or a shared uplink port set.
Syntax
remove uplinkport
UplinkSet=
Parameters
PortID (required) The ID of the port to remove from a network. The port ID must be in the format
If EnclosureID is not specified, it defaults to the local enclosure.
Properties
Network
(optional)
The name of the network from which the port is to be removed
UplinkSet
(optional)
The name of the shared uplink port set from which the port is to be removed
Examples
->remove uplinkport enc0:1:2 Network=MyNetwork
Removes a specific uplink port (Bay 1, Port 2) from a network
->remove uplinkport * Network=BlueNetwork
Removes all uplink ports from a network named "BlueNetwork"
->remove uplinkport enc0:2:3 UplinkSet=SharedUplinkSet1
Removes a specific uplink port (Bay 2, Port 3) from a shared uplink set
Item
Description
set uplinkport
Modify an uplink port that exists as a member of a network or shared uplink port set.
Syntax
set uplinkport
UplinkSet= sabled>] [Role= Parameter PortID (required) The ID of the port to modify. The specified port must already be added to a network or uplink port set. The port ID is in the format Properties Network (required) The name of the network to which the port belongs if the uplink set name is not UplinkSet (required) The name of the shared uplink port set to which the port belongs if the network name is Speed (optional) Specifies the port speed for the port. Acceptable values include "Auto", "10Mb", "100Mb", "1Gb", "10Gb", and "Disabled".
specified.
not specified.
If there is no connector present on the uplink port, only "Auto" and "Disabled" can be
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem