Name
RFC
Description
counter can occur at re-initialization
of the management system, and at
other times as indicated by the value
of ifCounterDiscontinuityTime.
rfc2665_Dot3ControlInUnkno
wnOpcodes
2665 A count of MAC Control frames
received on this interface that contain
an opcode that is not supported by
this device. Discontinuities in the
value of this counter can occur at
re-initialization of the management
system, and at other times as
indicated by the value of
ifCounterDiscontinuityTime.
rfc2665_Dot3InPauseFrames 2665 A count of MAC Control frames
received on this interface with an
opcode indicating the PAUSE
operation. This counter does not
increment when the interface is
operating in half-duplex mode.
Discontinuities in the value of this
counter can occur at re-initialization
of the management system, and at
other times as indicated by the value
of ifCounterDiscontinuityTime.
rfc2665_Dot3OutPauseFrame
s
2665 A count of MAC Control frames
transmitted on this interface with an
opcode indicating the PAUSE
operation. This counter does not
increment when the interface is
operating in half-duplex mode.
Discontinuities in the value of this
counter can occur at re-initialization
of the management system, and at
other times as indicated by the value
of ifCounterDiscontinuityTime.
rfc2665_Dot3StatsAlignmentE
rrors
2665 A count of frames received on a
particular interface that are not an
integral number of octets in length
and do not pass the FCS check. The
count represented by an instance of
this object is incremented when the
alignmentError status is returned by
the MAC service to the LLC (or other
MAC user). Received frames for
which multiple error conditions
obtain are, according to the
conventions of IEEE 802.3 Layer
Management, counted exclusively
according to the error status
presented to the LLC. This counter
does not increment for 8-bit wide
group encoding schemes.
Discontinuities in the value of this
counter can occur at re-initialization
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem