Firmware, Igmp, Interconnect – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 30
Command line 30
firmware
Display the Virtual Connection firmware version.
Support actions: help, show
show firmware
Display the firmware information for all interconnect modules in the domain.
Syntax
show firmware
Examples
->show firmware
Displays a summary listing of all firmware
->show firmware *
Displays a detailed listing of all firmware
To update firmware, use the HP BladeSystem c-Class Virtual Connect Support Utility. For more information on
installing the firmware, see the HP BladeSystem c-Class Virtual Connect Support Utility documentation on the
HP website
igmp
Manage Ethernet IGMP Snooping settings.
Supported actions: help, set, show
Item
Description
set igmp
Modify Ethernet IGMP Snooping settings.
Syntax
set igmp [Enabled=
Properties
Enabled
(optional)
Enables or disables IGMP Snooping. Valid values include "true" and "false".
Timeout
(optional)
The idle timeout interval (in seconds) for IGMP Snooping. Valid values include integers
from 1-3600. The default IGMP idle timeout is 260 seconds.
Examples
->set igmp Enabled=true
Enables IGMP Snooping
->set igmp Enabled=true Timeout=30
Enables IGMP Snooping and sets the idle timeout
Item
Description
show igmp
Display Ethernet IGMP Snooping settings.
Syntax
show igmp
Example
->show igmp
Displays IGMP Snooping settings
interconnect
Manage I/O interconnect modules.
Supported actions: help, remove, show
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem