HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 44
Command line 44
Item
Description
SNType (Optional)
The source of the serial number assignment to be used during the profile creation.
If not specified, the serial number is assigned according to the Virtual connect
default domain settings. Valid values include "Factory-Default" and "User-Defined".
SerialNumber
(required if the
SNType is
User-Defined)
A custom user-defined serial number associated with the server profile. When the
profile is assigned to a device bay that contains a server, the server inherits the
virtual serial number. The user-defined serial number must start with the pattern
VCX01.
UUID (Optional)
A unique 128-bit identifier for the virtual server ID. The format is
xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx, where x is any alpha-numeric character. If
no UUID is specified, then one is auto-generated. The UUID can be specified only if
the SNType is User-Defined.
Examples
->add profile MyNewProfile
Creates a new profile and adds it to the domain, using default connections and
Virtual Connect default serial numbers
->add profile MyNewProfile2 -NoDefaultEnetConn
Creates a new profile without adding default Ethernet connections
->add profile MyNewProfile2 -NoDefaultFcConn
Creates a new profile without adding default FC connections
->add profile MyNewProfile2 -NoDefaultEnetConn
-NoDefaultFcConn
Creates a new profile without adding default Ethernet and FC connections
->add profile MyNewProfile SNType=User-Defined
SerialNumber=VCX0113121
Creates a new profile and specifies a custom virtual serial number
->add profile MyNewProfile SNType=Factory-Default
Creates a new profile and uses the factory assigned serial number
->add profile MyNewProfile SNType=User-Defined
SerialNumber=VCX0113121
UUID=15713c60-fcf2-11dc-a656-0002a5d5c51b
Creates a new profile and specifies a custom virtual serial number and UUID
Item
Description
assign profile
Assign a server profile to a device bay.
Syntax
assign profile
Parameters
ProfileName
(required)
The unique name of the server profile to assign
DeviceBay (required) The device bay to assign the profile to, in the format
If EnclosureID is not specified, it defaults to the local enclosure.
To assign a profile to a multi-blade server,
Option
PowerOn
Powers on the server after the profile has been assigned.
Example
->assign profile MyProfile1 enc0:1
Assigns a profile to device bay 1 of the primary enclosure
->assign profile MyProfile1 enc0:5
Assigns a profile to a multi-blade server in bays 5-8 of the primary enclosure
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem