HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 65
Command line 65
Item
Description
Examples
->remove user steve
Removes a specific user by name
->remove user *
Removes all users
Item
Description
set user
Modify attributes of an existing user.
Syntax
set user
[ContactInfo=
[Privileges=
Parameter
UserName (required) The name of the user to be modified
Properties
Password (optional) The new password of the user can be entered as clear text in the command or as a
masked string at the prompt. If the Password value is blank, the user is prompted to
enter the password at the prompt.
FullName (optional) The full name of the user
ContactInfo
(optional)
Contact information for the user
Enabled (optional) Enables or disables the user. Valid values include "true" and "false".
Privileges
(optional)
The allowed privileges for the user. Privileges can be any combination of "domain",
"server", "network", "storage" separated by commas. If the privilege is blank, then
the user has no privileges and can display domain information only. If "*" is
specified, then all privileges apply.
Examples
->set user steve Password=fgY87hHl
Modifies an existing user password
->set user steve Password
Modifies an existing user password, masked, at the prompt
->set user bill Password=HGtwf7272562
Privileges="domain,network" FullName="Bill Johnson"
[email protected] Enabled=true
Modifies several properties of an existing user
->set user tom privileges=*
Gives a user all privileges
Item
Description
show user
Display user summary or user details.
Syntax
show user [
Parameter
UserName (optional) Name of an existing user in the VC domain. If not specified, then summary of all
existing user will be displayed.
Examples
->show user
Lists all existing users
->show user steve
Displays details of an existing user by name
->show user *
Displays details of all existing users
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem