Profile – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 43

Command line 43
Item
Description
"10Mb", "100Mb", "1Gb", "10Gb", and "Disabled". The default value is "Auto".
If there is no connector present on the analyzer port, only "Auto" and "Disabled"
can be configured as a possible speed. Speed restrictions apply.
Duplex (optional)
The port duplex mode of the network analyzer port. Valid values include "Auto",
"Half", and "Full". The default value is "Auto".
MonitorPort
(required if the
Direction property
is being modified)
The server port to be monitored. The format of the monitored port is
If the enclosure ID is not specified, the default enclosure is the local enclosure where
the domain resides.
Direction (optional) The direction of network traffic on the port being monitored. Valid values include
"ToServer", "FromServer", and "Both".
Examples
->set port-monitor AnalyzerPort=enc0:3:1 Speed=1Gb
Duplex=half
Modifies network analyzer uplink port properties
->set port-monitor MonitorPort=enc0:1:6 Direction=ToServer
Modifies a monitored server port
->set port-monitor Enabled=true
Enables port monitoring
->set port-monitor Enabled=false
Disables port monitoring
Item
Description
show port-monitor
Display the Virtual Connect port monitor configuration.
Syntax
show port-monitor
Example
->show port-monitor
Displays the port monitor configuration
profile
Manage server profiles.
Supported actions: add, assign, help, remove, set, show, unassign
Item
Description
add profile
Create a new server profile. After the profile has been created, the profile can then
be configured using the "set" subcommand, and the additional network and fabric
connections can also be added. The server profile can also be assigned to a device
bay using the "assign" subcommand.
Syntax
add profile
[-NoDefaultFcConn] [SNType=
[SerialNumber=
Parameter
ProfileName
The unique name of the new server profile to create
Options
NoDefaultEnetConn
Do not add default Ethernet Network connections when creating the server profile.
NoDefaultFcConn
Do not add default FC SAN connections when creating the server profile.
Properties
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem