Specifications, Switch specifications, Operating conditions – HP Storage EVA Capacity Upgrades User Manual
Page 41: A specifications, Aspecifications, Switch specifications operating conditions

30-10022-01 loop switch user guide
41
A
Specifications
Switch Specifications
Operating Conditions
The switch must be operated in a clean, dry environment with unrestricted airflow. Air flows in through
the cosmetic end and out through the business end (sometimes called the transceiver end or
“back-of-box”).
To avoid overheating, maintain a minimum clearance of two inches (50.8 millimeters) on each end of
the switch (the cosmetic end and the business end). Allow an adequate amount of space on the top
and sides of the switch for proper air ventilation. Do not place the switch on heat-generating surfaces.
Operating conditions are listed below.
Specification
Value
Number of Ports
12
Operating Rate
All ports operate independently at 1.0625 or 2.125 Gb/s
Port Media Type
SFP optical or copper based
Enclosure
1U half-rack form-factor
Management Interface
Fibre Channel, RS-232, or 10/100 Ethernet
EU Compliance
EU directive 2002/95/EC
Configurability
Management interface configurable
Power On Selftest (POST)
Yes
Dimensions
8.5" x 1.73" x 14.50" (W x H x D)
AC Power Input
50 or 60 Hz / 100 – 250 VAC / 1.0 – 0.5 A
AC Power Connector
IEC connector
Weight
Approximately 7 lbs.
Requirement
Value
Operating Temperature
0°C to 40°C normal operation (ambient air temperature)
Storage
-40°C to 80°C non-condensing
Power
50 or 60 Hz / 100 – 250 VAC / 1.0 – 0.5 A