9.

Remove the existing modules that are not FlexFabric from both horizontally adjacent bays
three to eight.

10. Add the two existing VC modules in both horizontally adjacent bays three and four with

appropriate FC SFP+ transceivers.

11. Create new networks with FC SAN fabrics linked to the new FlexFabric module uplink ports.
12. Reassign the Ethernet connections in server profiles or add new connections to the server

profiles, depending on what was selected in

Step 4

and

Step 7

.

13. Save the configuration again.

IMPORTANT:

HP recommends that you save the configuration so that if there is a problem

with the VC firmware upgrade you can restore the system to the last configuration snapshot.

14. Remove the Ethernet modules from bays one and two.
15. Add the two existing VC Ethernet modules in both horizontally adjacent bays one and two.
16. Follow the Virtual Connect Domain Setup Wizard, and select the option to restore the domain

for the saved configuration file in

“Replacing VC Ethernet and FC modules with FlexFabric

modules in an existing VCEM managed VC Domain” (page 51)

.

After performing all the steps in

“Replacing VC Ethernet and FC modules with FlexFabric modules

in an existing VCEM managed VC Domain” (page 51)

you can create, or edit any existing server

profiles and use the available networks or SAN Fabrics from the FlexFabric module to create iSCSI
connections.