Vc domain displays configuration mismatch status, Vc domain displays connectivity failure status – HP Virtual Connect Enterprise Manager Software User Manual
Page 111
3.
To disable the account, from the Virtual Connect Manager command prompt, enter
set external-manager Username=xyz Enabled=false
.
If the VC Domain firmware is 2.0x or later, perform the following:
•
To remove the account and release the VC Domain from VCEM control, from the Virtual
Connect Manager command prompt, enter
remove external-manager Username=xyz
mactype=
wwnType=
serverIdType=
serverIdEnd=<>
NOTE:
The “-quiet” option is used to suppress user confirmation prompts. This option is useful
for scripting operations. This option is available for VC firmware 2.0x or later for the disable
account, remove the account, and release ranges commands.
For more information, see the HP Virtual Connect Manager Command Line Interface User Guide.
VC Domain displays Configuration Mismatch status
If the VCEM data does not match the data from the VC Domain, then the Configuration Mismatch
icon appears. This might happen when either the user suspends the external manager lock and
then modifies the VC Domain, or adds or removes VC Modules from rear-enclosure interconnect
bays.
To correct this issue, see
“Resynchronizing a VC Domain with Configuration Mismatch” (page 48)
.
VC Domain displays Connectivity failure status
The Connectivity failure icon might appear if any of the following occur:
•
Connection timeout, network problems, Virtual Connect Ethernet Modules physically not
available, or enclosure problem
•
Virtual Connect Manager failover
•
VC Domain firmware update
•
Virtual Connect Ethernet Module IP address change.
To correct this issue, perform any of the following:
•
Ethernet VC modules are not physically available or there is a connection timeout or a network
problems between VCEM and VC Ethernet modules.
To correct this issue, verify the Ethernet VC Modules are still available and that there are no
network-related issues with the Virtual Connect Manager. From the command line at the VCEM
server, ping the VC Domain IP.
For information on enclosure problems, see
“Enclosure has a hardware failure and must be
.
•
In a redundant environment, the failover between active and standby Virtual Connect module
is taking place.
To correct this issue:
1.
Verify that the failover between the active and standby Virtual Connect module is taking
place.
2.
Wait a few minutes until the failover completes, and then try again.
3.
Log into the Virtual Connect Manager (https://
Connect Manager not at this IP address might appear.
VC Domain displays Configuration Mismatch status
111