Table 6 Management Area Capacity of a Mainframe Volume (continued)
Management Area Capacity
Emulation Type
22
3380-F
NOTE:
The management area capacity of a mainframe volume is expressed in cylinders.
Table 7 Management Area Capacity of an Open-Systems Volume
Management Area Capacity
Emulation Type
0
OPEN-V
5,760
OPEN-3
19,440
OPEN-8
19,440
OPEN-9
13,680
OPEN-E
NOTE:
The management area capacity of an open-systems volume is expressed in kilobytes.
Table 8 Boundary Value for Each RAID Level
Boundary Value for
RAID6 (6D+2P)
Boundary Value for
RAID5 (7D+1P)
Boundary Value for
RAID5 (3D+1P)
Boundary Value for
RAID1 (2D+2D)
Emulation Type
2,304
2,688
1,152
768
3380-xx
2,784
3,248
1,392
928
3390-xx
2,304
2,688
1,152
768
OPEN-xx
(except for OPEN-V)
3,072
3,584
1,536
1,024
OPEN-V
NOTE:
•
xx is a variable indicating one or more numbers or letters.
•
Boundary values are expressed in kilobytes.
•
Boundary values of external volumes are always one kilobyte, regardless of the RAID levels.
Table 9 Boundary Value for Each RAID Level (Data Protection Level is Set to Enhanced Mode on
SATA Drive)
Boundary Value for
RAID6 (6D+2P)
Boundary Value for
RAID5 (7D+1P)
Boundary Value for
RAID5 (3D+1P)
Boundary Value for
RAID1 (2D+2D)
Emulation Type
22,272
25,984
5,568
1,856
3390-xx
24,576
28,672
6,144
2,048
OPEN-V
NOTE:
•
xx is a variable indicating one or more numbers or letters.
•
Boundary values are expressed in kilobytes.
•
A SATA drive supports the following emulation types:
3390-xx for a mainframe system.
OPEN-V for an open system.
Overview of Virtual LVI/LUN