Monitoring System Activity and Performance

H2TU-C-319 List 4E

January 9, 2002

47

Table 18.

HDSL2 Alarm Descriptions

Screen Alarm

Front-Panel Alarm

Description

MTAE

MTAE

Metallic Test Access Equipment—The H2TU-C is in its MTA/LOSW test state.

MTAF

MTAF

Metallic Test Access Facility—The H2TU-C is in its MTA/LOSW test state.

LOSW

LOSW

Loss of Sync Word—The HDSL2 loop has lost synchronization.

MAL

xxx-MAL

Margin—The margin on the HDSL2 loop has dropped below the minimum threshold value
set for the system. (xxx denotes either TUC or TUR.)

LA

xxx-LA

Loop Attenuation—The attenuation on the HDSL2 loop has exceeded the maximum value
set for the HDSL2 loop attenuation threshold. (xxx denotes either TUC or TUR.)

HBER

xxx-HBER

Block Error Rate—The HDSL2 BER has exceeded the set threshold limits of 10

-6

or 10

- 7

.

(xxx denotes either TUC or TUR.)

SHORT

(a)

PWR FEED SHRT

Indicates a short between the Tip and Ring of the HDSL2 pair.

GND

(a)

(a) Displays only on the H2TU-C HDSL2 interface.

PWR FEED GND

The HDSL2 loop is grounded.

OPEN

(a)

PWR FEED OPEN

Indicates a line power open condition.