Monitoring System Activity and Performance
H2TU-C-319 List 4E
January 9, 2002
47
Table 18.
HDSL2 Alarm Descriptions
Screen Alarm
Front-Panel Alarm
Description
MTAE
MTAE
Metallic Test Access Equipment—The H2TU-C is in its MTA/LOSW test state.
MTAF
MTAF
Metallic Test Access Facility—The H2TU-C is in its MTA/LOSW test state.
LOSW
LOSW
Loss of Sync Word—The HDSL2 loop has lost synchronization.
MAL
xxx-MAL
Margin—The margin on the HDSL2 loop has dropped below the minimum threshold value
set for the system. (xxx denotes either TUC or TUR.)
LA
xxx-LA
Loop Attenuation—The attenuation on the HDSL2 loop has exceeded the maximum value
set for the HDSL2 loop attenuation threshold. (xxx denotes either TUC or TUR.)
HBER
xxx-HBER
Block Error Rate—The HDSL2 BER has exceeded the set threshold limits of 10
-6
or 10
- 7
.
(xxx denotes either TUC or TUR.)
SHORT
PWR FEED SHRT
Indicates a short between the Tip and Ring of the HDSL2 pair.
GND
(a)
(a) Displays only on the H2TU-C HDSL2 interface.
PWR FEED GND
The HDSL2 loop is grounded.
OPEN
PWR FEED OPEN
Indicates a line power open condition.