beautypg.com

Compatibility, Applications, Ompatibility – ADC HiGain H2TU-C-319 List 4E User Manual

Page 10: Pplications

background image

Overview

LTPH-UM-1049-02, Issue 2

2

January 9, 2002

H2TU-C-319 List 4E

Configuration options

Selectable DS1 pre-equalizer

Bipolar Violation Transparency (BPVT) options

Bit Error Rate (BER) alarm

Power Back Off Network (PBON) and Power Back Off Customer (PBOC) options for configuring output
levels

Loss of Signal/Alarm Indication Signal (LOS/AIS) payload alarm option

Remote provisioning

Compatible with HMS-358 Soneplex

®

Wideband 3190 shelves only

Digital Data Service (DDS) latching loopback

Network Management and Administration (NMA) interface

Metallic Test Access (MTA)

Dual DSX-1 port option

C

OMPATIBILITY

The H2TU-C has two unique features, Metallic Test Access and Dual DS1 port options, which are not provided
in standard ADC line units with 3192 mechanics. These features require additional access pins which are provided
by a special card-edge connector, shown in

Figure 33 on page 68

. Only the HMS-358 set of shelves can

accommodate this special connector.

A

PPLICATIONS

HiGain HDSL2 systems provide a cost-effective, easy-to-deploy method for delivering T1 High Capacity Digital
Service (HCDS) over a single copper pair. HiGain HDSL2 systems support a multitude of network connections
and system models.

The service is deployed over one unconditioned, non-loaded copper pair.

Conventional, inline DS1 repeaters are no longer required.

Cable pair conditioning, pair separation and bridged tap removal are not required.

Each loop has no more than 35 dB of loss at 196 kHz, with driving and terminating impedances of 135

. In

general, HiGain HDSL2 systems:

Operate effectively in the same cable binder group with other HDSL2 lines, HDSL, T1, ADSL, SDSL, POTS,
DDS, and other transmission schemes.

Can be used with customers requiring DS1 service on a temporary or permanent basis.

Provide a means of quickly deploying service in advance of fiber-optic transmission systems.

DS1 is used throughout this document to refer to either the remote unit’s DS1 interface or the
line unit’s DSX-1 interface.