H2tu-r ds1 alarm history screen, Ds1 alarm descriptions, Table 17 on – ADC HiGain H2TU-C-319 List 4E User Manual

Page 53

background image

LTPH-UM-1049-02, Issue 2

Monitoring System Activity and Performance

H2TU-C-319 List 4E

January 9, 2002

45

Figure 26.

H2TU-R DS1 Alarm History Screen

Table 17.

DS1 Alarm Descriptions

Screen Alarm

Front-Panel Alarm Description

H2TU-C DSI Alarms (see

Figure 25 on page 44

)

SPTE

Split Equipment

A test mode initiated by the HMU which splits the AUX port’s DSX-1 payload and sends it to the
MUX port.

SPTF

Split Facilities

A test mode initiated by the HMU which splits the AUX facility DS payload from the AUX port
#1 and sends it to the MUX port.

LLOS

(a)

LLOS

Local Loss of Signal—Loss of the H2TU-C DSX-1 input signal.

LAIS

LAIS

Line Alarm Indication Signal—Indicates an AIS (all ones) pattern is being detected at the
H2TU-C DS1 input port. The ALMP option determines whether AIS (default) or LOS is sent
towards the CPE.

DBER

xxx-DBER

Bit Error Rate—The DS1 BER has exceeded the built-in 24-hour threshold limits of
approximately 10

-6

. (xxx denotes either TUC or TUR.)

H2TU-R DS1 Alarms (see

Figure 26

above)

RLOS

(a)

RLOS

Remote Loss of Signal— Loss of the H2TU-R DS1 input signal.

RAIS

RAIS

Remote Alarm Indication Signal—AIS is being detected at the H2TU-R DS1 input port. By
default (see

Figure 30 on page 54

) AIS-CI

(b)

is sent toward the network.

RAI

RRAI

Remote Alarm Indication—Indicates an RAI alarm (yellow) from the CPE with errors from the
line unit or network.

TX RAI-CI

TRCI

Transmit RAI-CI - Remote Alarm Indication at the H2TU-R—Upon reception of an RAI (yellow
LED) from the CPE, the H2TU-R sends an RAI-CI towards the network if the network signal
received at the H2TU-R is clear. If the network signal is impaired (LOS, AIS or LOF), then the
RAI is passed on to the network unaltered. This is applicable to SF or ESF framing. In an all SF
environment, RACI must be enabled to convert SF-RAI to SF-RAI-CI.

PRM-NE

PRMN

Performance Report Monitoring - Near End—The count of the PRM-NE register at the H2TU-R
exceeds the 10

-6

BER threshold at 648 events since 12:00:00 AM.

PRM-FE

PRMF

Performance Report Monitoring - Far End—The count of the PRM-FE register at the H2TU-R
exceeds the 10

-6

BER threshold at 648 events since 12:00:00 AM.

Continued

Monitor

Performance

Event Log

Config

Inventory

Report

Rlogon

Help

H2TU-R DS-1 Alarm History

-----------------------------------------------------------------------------

Alarm

First

Last

Status

Count

RLOS

OK

0

RAIS

OK

0

RAI

OK

0

TX RAI-CI

OK

0

PRM-NE

OK

0

PRM-FE

OK

0

DBER

08/16/01 00:37

08/16/01 00:45

OK

7

Press: C(l)ear Alarm History

------------------------------------------------------------------------------

Use to cycle through

Interface

:

H2TU-R DS-1

choices and to view

Statistics :

Alarm History

ID: xxxx--xxxx--xxxx--xxxx

08/01/2001 07:05:33

H2TU-C

System: Alarm