lists the front-panel display messages. The four-character display reports the code of an alarm, loopback,
or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first
message with a value or current configuration setting.
Table 2.
Front-Panel Display Messages
Message
Full Name
Description
ALARM MESSAGES
ACO
Alarm Cut Off
A system alarm has occurred, and has been retired to an ACO
condition by pressing the LBK pushbutton on the H2TU-C front
panel.
ALRM
Alarm Condition Exists
A system alarm condition is in effect.
DBER
DS1 Bit Error Rate
A system DS1 BER alarm is in effect and remains in effect until cleared.
HBER
HDSL2 Block Error Rate
A system HDSL2 Block Error Rate alarm is in effect.
LA
Loop Attenuation
Indicates that the attenuation on the HDSL2 loop has exceeded the
maximum threshold value.
LAIS
Local Alarm Indication Signal
Indicates an AIS (all ones) pattern is being received or transmitted
at the H2TU-C DS1 input or output ports.
LLOS
Local Loss of Signal
Indicates that no signal is detected at the DSX-1 input to the
H2TU-C. Causes a system alarm.
LOSW
Loss of Sync Word
Indicates that the HDSL2 loop has lost synchronization.
MAL
Margin Alarm
The margin on HDSL2 loop has dropped below the threshold
(0 to 15 dB) as set by the operator.
MTA
Metallic Test Access
Indicates the H2TU-C is in a metallic test access state.
PWR FEED GND
Power Feed Ground
The HDSL2 loop is grounded.
PWR FEED OPEN
Power Feed Open
Indicates a line power open condition.
PWR FEED SHRT
Power Feed Short
Indicates a short between the Tip and Ring of the HDSL2 pair.
PRMF
Performance Report Messaging - Far
End
H2TU-R PRM-FE BER threshold has been exceeded.
PRMN
Performance Report Messaging - Near
End
H2TU-R PRM-NE BER threshold has been exceeded.
RAIS
Remote Alarm Indication Signal
Indicates an AIS (all ones) pattern is being received or transmitted
at the H2TU-R DS1 input or output ports.
RLOS
Remote Loss of Signal
Indicates that no signal is detected at the DS1 input to the H2TU-R.
Causes a system alarm.
RRAI
Remote RAI—Remote Alarm
Indication at the H2TU-R (Net signal
has errors.)
Indicates an RAI alarm (yellow LED) from the CPE with errors from
the line unit or network.
SPN1
Span Number
Accompanies the LOSW alarm and identifies the span where the
LOSW alarm occurred.
TRCI
Transmit RAI-CI—TX RAI-CI
Indication - Customer Installation at
the H2TU-R (Net signal does not have
errors.)
Upon reception of an RAI (yellow LED) from the CPE, the H2TU-R
sends RAI-CI toward the network if the network signal received at the
H2TU-R is clear. If the network signal is impaired (LOS, AIS, or Loss
of Frame [LOF]), then the RAI is automatically passed on to the
network.
TUC
Transmission Unit Central Office
Accompanies the HBER, MAL, and LA alarm and indicates that the
alarm has occurred at the H2TU-R remote unit.
TUR
Transmission Unit Remote End
Accompanies the HBER, MAL, and LA alarm and indicates that the
alarm has occurred at the H2TU-R remote unit.