LTPH-UM-1049-02, Issue 2

Front Panel

H2TU-C-319 List 4E

January 9, 2002

5

Table 2

lists the front-panel display messages. The four-character display reports the code of an alarm, loopback,

or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first
message with a value or current configuration setting.

Table 2.

Front-Panel Display Messages

Message

Full Name

Description

ALARM MESSAGES

ACO

Alarm Cut Off

A system alarm has occurred, and has been retired to an ACO
condition by pressing the LBK pushbutton on the H2TU-C front
panel.

ALRM

Alarm Condition Exists

A system alarm condition is in effect.

DBER

DS1 Bit Error Rate

A system DS1 BER alarm is in effect and remains in effect until cleared.

HBER

HDSL2 Block Error Rate

A system HDSL2 Block Error Rate alarm is in effect.

LA

Loop Attenuation

Indicates that the attenuation on the HDSL2 loop has exceeded the
maximum threshold value.

LAIS

Local Alarm Indication Signal

Indicates an AIS (all ones) pattern is being received or transmitted
at the H2TU-C DS1 input or output ports.

LLOS

Local Loss of Signal

Indicates that no signal is detected at the DSX-1 input to the
H2TU-C. Causes a system alarm.

LOSW

Loss of Sync Word

Indicates that the HDSL2 loop has lost synchronization.

MAL

Margin Alarm

The margin on HDSL2 loop has dropped below the threshold
(0 to 15 dB) as set by the operator.

MTA

Metallic Test Access

Indicates the H2TU-C is in a metallic test access state.

PWR FEED GND

Power Feed Ground

The HDSL2 loop is grounded.

PWR FEED OPEN

Power Feed Open

Indicates a line power open condition.

PWR FEED SHRT

Power Feed Short

Indicates a short between the Tip and Ring of the HDSL2 pair.

PRMF

Performance Report Messaging - Far
End

H2TU-R PRM-FE BER threshold has been exceeded.

PRMN

Performance Report Messaging - Near
End

H2TU-R PRM-NE BER threshold has been exceeded.

RAIS

Remote Alarm Indication Signal

Indicates an AIS (all ones) pattern is being received or transmitted
at the H2TU-R DS1 input or output ports.

RLOS

Remote Loss of Signal

Indicates that no signal is detected at the DS1 input to the H2TU-R.
Causes a system alarm.

RRAI

Remote RAI—Remote Alarm
Indication at the H2TU-R (Net signal
has errors.)

Indicates an RAI alarm (yellow LED) from the CPE with errors from
the line unit or network.

SPN1

Span Number

Accompanies the LOSW alarm and identifies the span where the
LOSW alarm occurred.

TRCI

Transmit RAI-CI—TX RAI-CI
Indication - Customer Installation at
the H2TU-R (Net signal does not have
errors.)

Upon reception of an RAI (yellow LED) from the CPE, the H2TU-R
sends RAI-CI toward the network if the network signal received at the
H2TU-R is clear. If the network signal is impaired (LOS, AIS, or Loss
of Frame [LOF]), then the RAI is automatically passed on to the
network.

TUC

Transmission Unit Central Office

Accompanies the HBER, MAL, and LA alarm and indicates that the
alarm has occurred at the H2TU-R remote unit.

TUR

Transmission Unit Remote End

Accompanies the HBER, MAL, and LA alarm and indicates that the
alarm has occurred at the H2TU-R remote unit.