beautypg.com

ADC HiGain H2TU-C-319 List 4E User Manual

Page 14

background image

Front Panel

LTPH-UM-1049-02, Issue 2

6

January 9, 2002

H2TU-C-319 List 4E

LOOPBACK MESSAGES

CLOC

Customer Local Loopback

Signal from customer is looped back to the customer at the
H2TU-R.

CREM

Customer Remote Loopback

Signal from customer is looped back to the customer at H2TU-C.

NLOC

Network Local Loopback

DSX-1 signal is looped back to the network at the H2TU-C.

NREM

Network Remote Loopback

DSX-1 signal is looped back to the network at the H2TU-R.

SMJK

Remote SmartJack Loopback

DSX-1 signal is looped back to the network at the H2TU-R
SmartJack module.

DIAGNOSTIC MESSAGES

A = xx

Maximum Loop Attenuation

The Attenuation (A) message appears followed by xx, where xx is
the loop attenuation of the longest (maximum loss) span, measured
in dB.

ACQ

Acquisition

The multiplexers of the H2TU-C and H2TU-R (or the H2TU-C and
first regenerator) are trying to establish synchronization over the
HDSL2 loop of Span 1.

ARM

HiGain System Armed

Armed to respond to Intelligent Repeater Loop (ILR) codes.

BAD RT?

No Response from H2TU-R

The H2TU-C receives no response from the H2TU-R and all HDSL2
loop conditions are normal. Therefore, the integrity of the H2TU-R
or the HDSL2 loop is questionable.

FERR

Framing Bit Error Occurred

Framing bit error occurred at H2TU-C DSX-1 input.

FLDL

Flash Download

Flash download of firmware upgrades. Contact Customer Service
for upgrade procedures (see

“Appendix D - Product Support” on

page 75

).

HES

HDSL2 CRC Error

H2TU-C HDSL2 Loop Cyclical Redundancy Check (CRC) error.

LBPV

Local Bipolar Violation

A bipolar violation has been received at the DSX-1 input to the
H2TU-C.

M=xx

HDSL2 Loop Margin

Indicates the power of the received HDSL2 signal relative to noise
(S/N with respect to 21.5 dB). Any value of 6 dB or greater is
adequate for reliable system operation.

MNGD

Managed

The H2TU-C is under control of the HMU-319 Network management
unit. In this state, the front-panel craft port and pushbuttons are
disabled.

PWR FEED OFF

Power Feed Off

HDSL2 span power has been turned off by setting the PWFD option
to off, or HDSL2 span power has been turned off by use of the A2LB
Intelligent Office Repeater (IOR) Power Down code.

PWR FEED ON

Power Feed On

Indicates that the HDSL2 loop is not grounded or shorted.

SIG

Signaling

The transceivers of the H2TU-C and H2TU-R (or the H2TU-C and
first regenerator) are trying to establish contact with each other over
the HDSL2 loop of Span 1.

Continued

Table 2.

Front-Panel Display Messages (Continued)

Message

Full Name

Description