ADC HiGain H2TU-C-319 List 4E User Manual
Page 14

Front Panel
LTPH-UM-1049-02, Issue 2
6
January 9, 2002
H2TU-C-319 List 4E
LOOPBACK MESSAGES
CLOC
Customer Local Loopback
Signal from customer is looped back to the customer at the
H2TU-R.
CREM
Customer Remote Loopback
Signal from customer is looped back to the customer at H2TU-C.
NLOC
Network Local Loopback
DSX-1 signal is looped back to the network at the H2TU-C.
NREM
Network Remote Loopback
DSX-1 signal is looped back to the network at the H2TU-R.
SMJK
Remote SmartJack Loopback
DSX-1 signal is looped back to the network at the H2TU-R
SmartJack module.
DIAGNOSTIC MESSAGES
A = xx
Maximum Loop Attenuation
The Attenuation (A) message appears followed by xx, where xx is
the loop attenuation of the longest (maximum loss) span, measured
in dB.
ACQ
Acquisition
The multiplexers of the H2TU-C and H2TU-R (or the H2TU-C and
first regenerator) are trying to establish synchronization over the
HDSL2 loop of Span 1.
ARM
HiGain System Armed
Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT?
No Response from H2TU-R
The H2TU-C receives no response from the H2TU-R and all HDSL2
loop conditions are normal. Therefore, the integrity of the H2TU-R
or the HDSL2 loop is questionable.
FERR
Framing Bit Error Occurred
Framing bit error occurred at H2TU-C DSX-1 input.
FLDL
Flash Download
Flash download of firmware upgrades. Contact Customer Service
for upgrade procedures (see
“Appendix D - Product Support” on
).
HES
HDSL2 CRC Error
H2TU-C HDSL2 Loop Cyclical Redundancy Check (CRC) error.
LBPV
Local Bipolar Violation
A bipolar violation has been received at the DSX-1 input to the
H2TU-C.
M=xx
HDSL2 Loop Margin
Indicates the power of the received HDSL2 signal relative to noise
(S/N with respect to 21.5 dB). Any value of 6 dB or greater is
adequate for reliable system operation.
MNGD
Managed
The H2TU-C is under control of the HMU-319 Network management
unit. In this state, the front-panel craft port and pushbuttons are
disabled.
PWR FEED OFF
Power Feed Off
HDSL2 span power has been turned off by setting the PWFD option
to off, or HDSL2 span power has been turned off by use of the A2LB
Intelligent Office Repeater (IOR) Power Down code.
PWR FEED ON
Power Feed On
Indicates that the HDSL2 loop is not grounded or shorted.
SIG
Signaling
The transceivers of the H2TU-C and H2TU-R (or the H2TU-C and
first regenerator) are trying to establish contact with each other over
the HDSL2 loop of Span 1.
Continued
Table 2.
Front-Panel Display Messages (Continued)
Message
Full Name
Description