beautypg.com

ADC HiGain H2TU-C-319 List 4E User Manual

Page 26

background image

Provisioning

LTPH-UM-1049-02, Issue 2

18

January 9, 2002

H2TU-C-319 List 4E

Table 5

describes the Standard Config screen options and lists their front-panel display codes.

Table 6 on page 19

describes the ADC Config screen options and lists their front-panel display codes. Selections in bold typeface are
the factory default settings.

Table 5.

H2TU-C-319 List 4E Standard Config Menu Options

Standard Config
Menu Options

Front-Panel
Display
Code

Selection

Description

Loopback Timeout

LBTO

NONE

Disables automatic time-out cancellation of all loopbacks.

20

Sets automatic cancellation of all loopbacks to 20 minutes after initiation.

60

Sets automatic cancellation of all loopbacks to 60 minutes after initiation.

120

Sets automatic cancellation of all loopbacks to 120 minutes after initiation.

Loop Attenuation
Threshold

LATT

0 through
40 dB

Determines the maximum loop attenuation before an alarm is declared. Zero
disables the alarm. The loop attenuation threshold can only be set through the
maintenance screens.

32 dB

Default value. Zero disables the alarm.

Margin Threshold

MARG

0 to 15 dB

Determines the minimum allowable margin below which a system alarm can
occur. Zero disables the alarm.

The Margin Alarm Threshold can only be set through the maintenance
screens.

5 dB

Default value.

DS1 Frame
Formatting

FRMG

AUTO

Configures the line unit to operate in an auto-framing (AUTO) mode.

It detects and locks to both SF or ESF DS1 frame patterns. Line and path
performance parameters are maintained and displayed. Unframed payloads
will cause the ES-P and SES-P counters to increment.

UNFR

Configures the same as AUTO except unframed payloads do not cause the
ES-P and SES-P counters to increment.

DS1 Line Coding

DS1

B8ZS

Places both the H2TU-C and H2TU-R into their B8ZS modes.

AMI

Places both the H2TU-C and H2TU-R into their AMI modes.

H2TU-C Equalization

See

“H2TU-C

Equalization (EQL)
Option.” on page 22

.

EQL

0 ft

Sets the Equalizer to DSX-1 for 0 to 132 feet.

133 ft

Sets the Equalizer to DSX-1 for 133 to 265 feet.

266 ft

Sets the Equalizer to DSX-1 for 266 to 398 feet.

399 ft

Sets the Equalizer to DSX-1 for 399 to 532 feet.

533 ft

Sets the Equalizer to DSX-1 for 533 to 655 feet.

H2TU-R Line
Buildout

RLBO

0 dB

Sets the DS1 RLBO level toward the Customer Interface (CI).

-7.5 dB

Sets the DS1 RLBO level toward the CI to -7.5 dB.

-15 dB

Sets the DS1 RLBO level toward the CI to -15 dB.

Alarm Pattern

See

“Alarm Pattern

(ALMP) Option.” on
page 22

.

ALMP

AIS

Enables the HiGain HDSL2 system to output an AIS payload at its DS1 ports
for LOSW and LOS DS1. For priority resolution, see

Figure 30 on page 54

for

LOS/AIS response priorities.

LOS

Enables the HiGain HDSL2 system to output an LOS condition at its DS1 ports
for LOSW and LOS DS1.

H2TU-R TLOS
Loopback

TLOS

ENA

Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input,
if enabled at the H2TU-R. For priority resolution, see

Figure 30 on page 54

.

DIS

Disables TLOS logic loopback.

Power Back Off
Network

PBON

DEF

Configures the power output levels of the H2TU-C network unit towards the
customer to comply with the Default template as defined in Section 6.1.4.2 of
ANSIT1.E1.4.

ENH

Configures the power output levels of the H2TU-C network unit towards the
customer to comply with the Enhanced template as defined in Section 6.1.4.2
of ANSIT1.E1.4.

Continued