ADC HiGain H2TU-C-319 List 4E User Manual
Page 26
Provisioning
LTPH-UM-1049-02, Issue 2
18
January 9, 2002
H2TU-C-319 List 4E
describes the Standard Config screen options and lists their front-panel display codes.
describes the ADC Config screen options and lists their front-panel display codes. Selections in bold typeface are
the factory default settings.
Table 5.
H2TU-C-319 List 4E Standard Config Menu Options
Standard Config
Menu Options
Front-Panel
Display
Code
Selection
Description
Loopback Timeout
LBTO
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
Loop Attenuation
Threshold
LATT
0 through
40 dB
Determines the maximum loop attenuation before an alarm is declared. Zero
disables the alarm. The loop attenuation threshold can only be set through the
maintenance screens.
32 dB
Default value. Zero disables the alarm.
Margin Threshold
MARG
0 to 15 dB
Determines the minimum allowable margin below which a system alarm can
occur. Zero disables the alarm.
The Margin Alarm Threshold can only be set through the maintenance
screens.
5 dB
Default value.
DS1 Frame
Formatting
FRMG
AUTO
Configures the line unit to operate in an auto-framing (AUTO) mode.
It detects and locks to both SF or ESF DS1 frame patterns. Line and path
performance parameters are maintained and displayed. Unframed payloads
will cause the ES-P and SES-P counters to increment.
UNFR
Configures the same as AUTO except unframed payloads do not cause the
ES-P and SES-P counters to increment.
DS1 Line Coding
DS1
B8ZS
Places both the H2TU-C and H2TU-R into their B8ZS modes.
AMI
Places both the H2TU-C and H2TU-R into their AMI modes.
H2TU-C Equalization
See
Equalization (EQL)
Option.” on page 22
EQL
0 ft
Sets the Equalizer to DSX-1 for 0 to 132 feet.
133 ft
Sets the Equalizer to DSX-1 for 133 to 265 feet.
266 ft
Sets the Equalizer to DSX-1 for 266 to 398 feet.
399 ft
Sets the Equalizer to DSX-1 for 399 to 532 feet.
533 ft
Sets the Equalizer to DSX-1 for 533 to 655 feet.
H2TU-R Line
Buildout
RLBO
0 dB
Sets the DS1 RLBO level toward the Customer Interface (CI).
-7.5 dB
Sets the DS1 RLBO level toward the CI to -7.5 dB.
-15 dB
Sets the DS1 RLBO level toward the CI to -15 dB.
Alarm Pattern
See
.
ALMP
AIS
Enables the HiGain HDSL2 system to output an AIS payload at its DS1 ports
for LOSW and LOS DS1. For priority resolution, see
for
LOS/AIS response priorities.
LOS
Enables the HiGain HDSL2 system to output an LOS condition at its DS1 ports
for LOSW and LOS DS1.
H2TU-R TLOS
Loopback
TLOS
ENA
Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input,
if enabled at the H2TU-R. For priority resolution, see
.
DIS
Disables TLOS logic loopback.
Power Back Off
Network
PBON
DEF
Configures the power output levels of the H2TU-C network unit towards the
customer to comply with the Default template as defined in Section 6.1.4.2 of
ANSIT1.E1.4.
ENH
Configures the power output levels of the H2TU-C network unit towards the
customer to comply with the Enhanced template as defined in Section 6.1.4.2
of ANSIT1.E1.4.
Continued