beautypg.com

HP Smart Update Manager User Manual

Page 9

background image

HP deliverable

HP SUM command

Description

Scenario

Target2 -username

User1 -password

PW1

HP Integrity BL8x0c
i2, rx2800 i2, and
Superdome 2 Servers
Bundles for Windows
and Linux

Need to update all
enclosure firmware

Need to target VMware
host servers

HP Service Pack for
ProLiant

Offline:

SmartStart Scripting
Toolkit (G7 and older)

Scripting Toolkit (Gen8
and older)

The HP SPP and Smart
Update Firmware DVD take
care of this automatically

Use this scenario when you:

Automatic Deployment to
one or more servers in a HP
BladeSystem enclosure

Online:

None

Do not have an operating
system installed on a
server blade

Use the HP Smart Update
Firmware DVD or HP SPP

Offline:

HP Smart Update
Firmware DVD

Want an automatic way
to deploy firmware
updates

with embedded HP SUM to
deploy firmware updates to
one or more blades
automatically.

HP Service Pack for
ProLiant

Do not require log files
or user interaction with
the installation process

Want to update multiple
blades in an enclosure in
a single operation

The same scenario as shown
in the “Interactive, graphical

Update an existing enclosure
manually

Online:

Windows:

hpsum

HP Smart Update
Firmware DVD

deployment to a remote
host” or “Scripted

For more information, see
the HP CloudSystem Matrix

Linux:

./hpsum

deployment to a remote
host” scenarios discussed
previously in this table

HP Service Pack for
ProLiant

Compatibility website at

http://www.hp.com/go/
matrixcompatibility

.

Offline:

HP Smart Update
Firmware DVD

HP Service Pack for
ProLiant

Deploying firmware for ProLiant servers using the Service Pack for ProLiant

SPP is a re-packaging of HP ProLiant system software and firmware for ProLiant ML/DL/SL servers
and their options, and BladeSystem enclosures including OA,VC, and 3 GB SAS switches running
supported Windows, Linux, and VMware operating systems. The single SPP image contains a
comprehensive collection of firmware and system software components including drivers, agents,
non-agents, utilities, and firmware that is tested, managed, and deployed together as a single
solution.

NOTE:

HP SUM can detect updates that are available for a VMware server and generate reports,

it cannot deploy updates.

SPP includes HP SUM for deployment of the SPP components.

For a complete list of HP ProLiant systems and software supported by SPP, see the HP Service Pack
for ProLiant Release Notes
on the HP SPP website at

http://www.hp.com/go/spp/documentation

.

Deploying HP SUM

9