background image

Description

Targets

To update multiple VCs with different user names and
passwords, or VCs with OAs that have different credentials,
use the corresponding input files OAUID and OAPWD.

Provides the password credential for OA associated with
VC specified with the "target" command-line parameter.

/_password

Only one set of OA credentials can be specified with
command-line parameters. You can add multiple VC targets
to command-line parameters with the "target" parameter
only if the credentials of OAs associated with specified
VCs are the same. The argument oa_password is not
required if VC has the same credentials as the associated
OA. You do not need to provide an OA network address
associated with VC. HP SUM queries it from a specified
VC target.

To update multiple VCs with different user names and
passwords, or VCs with OAs that have different credentials,
use the corresponding input files OAUID and OAPWD .

Description

Log files

Redirects the output from HP SUM or the HP BladeSystem
c-Class OA flash utility to a different directory than the
default location.

/logdir

“path"

For Windows components, the default location is
%SYSTEMDRIVE%\CPQSYSTEM\hp\

log

and the redirected location is

\hp\log\

.

For Linux components, the default location is /var/hp/
log/

and the redirected location is

/hp/log/

.

Sets the verbosity level for the HP SUM execution log file,
hpsum_execution_log__

. It

/v[erbose]

or /veryv[erbose]

increases the level of detail that is retained in the log file.
The default value is normal verbosity.

Description

Generating reports

Generates a report listing of the target summary and
describes how the components in the repository affect the

/report

target; for example, whether each component applies to
the target. The report is generated in HTML and XML with
file name formats of
HPSUM_Report__

and

HPSUM_Report__

By default, the files are located in the present working
directory where HP SUM is initiated. If that location is
write-protected, you can find the files in the same directory
as the HP SUM log files.

Generates a report listing of the components in the
specified repository. The report is generated in HTML and

/inventory_report

XML with file name formats of
HPSUM_Inventory_Report__

.

By default, the report is located in the present working
directory where HP SUM is initiated. If that location is

38

Using scripts to deploy updates