Scripted deployment 50

COMPONENTSLIST = cp001234.exe, cp001235.exe
BUNDLESLIST = bp001234.xml
ALLOWUPDATEBUNDLE = YES
SKIPTARGET = NO
IGNOREERRORS = ServerNotFound, FailedDependencies
SOURCEPATH = c:\pkgsource1
USELATEST = YES
SILENT = YES
OPTIONS = /f:rom

[TARGETS]
HOST = schinta1
HOST = schinta2
UID = root
PWD = root123
HOST = 234.567.765.432
[END]

USAGE: hpsum /inputfile
Examples of inputfile.txt file:
Example 1: The two targets are passed to be updated. The targets do not necessarily have to be OAs. They
can be any target supported by HP SUM.

DRYRUN = YES
SILENT = YES
[TARGETS]
HOST = BL465C-01
HOST = 192.168.1.2
[END]

Example 2: A host DNS is passed along with the user ID and password to use for the hosts in the group.

DRYRUN = YES
SILENT = YES
[TARGETS]
HOST = BL685cG6
UID = Bigboss2
PWD = password
[END]

Example 3

SILENT = YES