beautypg.com

Other settings -5, P. 4-5) – Canon VB-M40 User Manual

Page 35

background image

4

-5

4

S

et

ting Page

Administrator Password

1

[Password]
Set the administrator password. Up to eight (single-

byte) ASCII characters (space or printable characters)

can be used. The factory default setting is “camera.”

If the Admin Viewer, Admin Tools, etc., are connected,

terminate the connection before changing the

password.

2

[Confirm Password]
Enter the same password as above for confirmation.

LAN

1

[LAN Interface]
Select [Auto], [Full Duplex] or [Half Duplex]. Normally

[Auto] is used.

2

[Maximum Packet Size]
Enter the maximum transmission unit. Normally there is

no need to change the default setting of 1500.

Note

• When using optical fiber or ADSL, setting the maximum packet

size to a slightly lower value may increase sending efficiency.

IPv4

1

[IPv4 Address Setting Method]

Select [Manual] or [Auto (DHCP)] in the address

setting method. If [Manual] is selected, directly enter

the values according to the environment in which the

camera is used. If [Auto (DHCP)] is selected, the value

automatically acquired from the DHCP server will be

entered in [IPv4 IP Address], [Subnet Mask] and [IPv4

Default Gateway Address].

2

[IPv4 Address]
If [Manual] is specified in 1, enter a fixed IP address.

3

[Subnet Mask]
If [Manual] is specified in 1, enter the designated

subnet mask values for each network.

4

[IPv4 Default Gateway Address]
Enter an appropriate value if [Manual] is specified in

1

. Be sure to set when connecting the camera to a

different subnet from that of the viewer.

[Network]
Administrator Password and LAN, IP Address, DNS and Other Settings

The following can be set here.

• Administrator Password

Set the administrator password.

• LAN

Set the IP address and other items needed to

establish a LAN connection.

• IPv4

Set IPv4 address.

• IPv6

Set IPv6 address.

• DNS

Set the name server address, host name and

DDNS registration.

• SNMP

Configure the necessary settings to use SNMP.

Important

• To ensure system security, be sure to change the

administrator password. Do not forget the new password.

• Press the reset switch to restore factory default settings if you

have forgotten the administrator password (P. 7-21). Note,

however, that this will reset all camera settings to factory

default settings except for date and time.

Important

• The camera may become inaccessible from the active web

browser if [LAN Interface] or [Maximum Packet Size] settings
are changed. Check beforehand the precautions in

“Important” in “[Reboot Item] Setting Items Requiring

Rebooting (P. 4-32).

• Set [Maximum Packet Size] to 1280 or greater if using IPv6.