Page 5

Table 3-4: I/O Characteristics

Parameter

Value

Communication
Interface

TCM XB

RS232 UART

TCM MB

CMOS/TTL UART

Communication Protocol

PNI Binary

Communication Rate

300 to 115200 baud

Maximum Sample Rate

1

~30 samples/sec

Time to Initial
Good Data

2

Initial power up

<210 ms

Sleep Mode recovery

<80 ms

Footnotes:

1. The maximum sample rate is dependent on the strength of the magnetic

field, and typically will be from 25 to 32 samples/sec.

2. FIR taps

set to “0”.


Table 3-5: Environmental Requirements

Parameter

Value

Operating Temperature

1

-40C to +85C

Storage Temperature

-40C to +85C

Footnote:

1. To meet performance specifications across this range,

recalibration will be necessary as the temperature varies.

Table 3-6: Mechanical Characteristics

Parameter

Value

Dimensions
(l x w x h)

TCM XB

35 x 43 x 13 mm

TCM MB

33 x 31 x 13 mm

Weight

TCM XB

6.8 gm

TCM MB

5.3 gm

Connector

TCM XB

9-pin Molex, pn 53780-0970

TCM MB

4-pin MIL-MAX, pn 850-10-004-10-001000