Table 6.10

6.19

MTL5043 repeater power supply
dual output, 4 to 20mA for 2-wire
transmitters

The MTL5043 provides fully-floating dc supplies for a single
conventional 2-wire 4 to 20mA transmitter located in a hazardous area
and driving two safe-area loads. The MTL5043 design changed to
add HART functionality at the end of 2003.

6.19.1

Wiring connections (earlier non-HART version)

See figure 6.40 for wiring connections.

6.19.2

Wiring connections (HART version)

See figure 6.41 for wiring connections.

22

INM5000-6 Jul 2010

Current

Current

Voltage

Voltage

Output

reading

reading

(terminal 2 with respect

(terminal 2 with respect

current

(A1)

(A1)

to terminal 1)

to terminal 1)

(A2)

(MTL5041)

(MTL5042)

(MTL5041)

(MTL5042)

4 to 20mA

<±20µA

<±10µA

20mA

>16.5V

>16.5V

6.19.3

Testing

Make the safe- and hazardous-area connections shown in figure 6.42
and, using RVI to vary the output current, carry out the following checks:

6.20

MTL5044 repeater power supply

The MTL5044 provides fully-floating dc supplies for two conventional 2-
wire 4 to 20mA transmitters located in a hazardous area and repeating
the current in two floating circuits to drive two safe-area loads.

6.20.1

Wiring connections

See figure 6.43 for wiring connections.

Safe area

Figure 6.40: MTL5043 wiring diagram and connections

Hazardous area

Safe area

Hazardous area

7
8
9

6
5
4
3
2
1

13
14

10
11
12

I

I

I

Vs–
Vs+

20 to 35V dc

+

–

4/20mA

–

4/20mA

Load

+

–

4/20mA

Load

+

HHC

HHC

7
8
9

6
5
4
3
2
1

13
14

10
11
12

I

I

I

V

Vs–
Vs+

20 to 35V dc

+

–

4/20mA

–

4/20mA

Load 2

+

–

4/20mA

Load 1

+

+

–

4/20mA

current

source mode

current

sink mode

Figure 6.41: MTL5043 wiring diagram and connections

Terminal

Function

1

Input –ve

2

Input +ve

7

Output –ve (Ch 2 passive current sink)

8

Output –ve (Ch 2 active/+ve current sink)

9

Output +ve (Ch 2 active)

10

Output +ve (Ch 1 via 220

Ω for HART apps.)

11

Output –ve (Ch 1)

12

Output +ve (Ch 1)

13

Supply –ve

14

Supply +ve

6
5
4
3
2
1

7
8
9

10
11
12

13
14

I

I

I

I

Ch 2

Ch 1

Vs–
Vs+

20 to 35V dc

–

4/20mA

Load

+

–

4/20mA

Load

+

+

–

4/20mA

+

–

4/20mA

Ch 2

Ch 1

Figure 6.43: MTL5044 wiring diagram and connections

Hazardous area

Safe area

Output

Current

Voltage

current

reading

terminal 2 with

(A2)

(A1)

respect to terminal 1)

4 to 20mA

<±20µA

20mA

>16.5V

6
5
4
3
2
1

7

8

9

10

11

12

13

14

I

I

I

Vs–
Vs+

20 to 35V dc

10kW lin

RV1

A1

A2

–

+

–

+

Output 1

Output 2

–

+

Figure 6.42: Test circuit for MTL5043

Terminal

Function

1

Input –ve (Ch 1)

2

Input +ve (Ch 1)

4

Input –ve (Ch 2)

5

Input +ve (Ch 2)

8

Output –ve (Ch 2)

9

Output +ve (Ch 2)

11

Output –ve (Ch 1)

12

Output +ve (Ch 1)

13

Supply -ve

14

Supply +ve

Terminal

Function

1

Input –ve

2

Input +ve

8

Output –ve (Ch 2)

9

Output +ve (Ch 2)

11

Output –ve (Ch 1)

12

Output +ve (Ch 1)

13

Supply –ve

14

Supply +ve

This manual is related to the following products: