Name
Total2_ReloadVolStop
Total2_ReloadDelay
Total2_10SecBackUp
Total2_Reserved
Flow_Pulse_Mode
PulseFlowStart
Units_Per_Pulse
Active_Low_Time
Flow_Pulse_Reserved
FlowCondMode
Flow_NRF_NSample
Flow_NRF_ErrLimit
Flow_NRF_TimeLimit
Flow_Damping
Flow_Window
FlowLinearizer
Flow_SC_Reserved
FlowTbl[0]. FlowPFSIn
FlowTbl[0]. FlowPFSOut
FlowTbl[1]. FlowPFSIn
FlowTbl[1]. FlowPFSOut
FlowTbl[2]. Flow PFSIn
FlowTbl[2]. Flow PFSOut
FlowTbl[3]. Flow PFSIn
FlowTbl[3]. Flow PFSOut
FlowTbl[4]. FlowPFSIn
FlowTbl[4]. FlowPFSOut
FlowTbl[5]. FlowPFSIn
FlowTbl[5]. FlowPFSOut
FlowTbl[6]. FlowPFSIn
FlowTbl[6]. FlowPFSOut
FlowTbl[7]. FlowPFSIn
FlowTbl[7]. FlowPFSOut
FlowTbl[8]. FlowPFSIn
FlowTbl[8]. FlowPFSOut
FlowTbl[9]. FlowPFSIn
FlowTbl[9]. FlowPFSOut
FlowTbl[10]. FlowPFSIn
FlowTbl[10]. FlowPFSOut
MDSerialNumber
MeterFSRange
LowFlowCutOff
FlowPowerUpDelay
Density
FluidName[20]
CalibratedBy[20]
CalibratedAt[20]
DateCalibrated[12]
DateCalibratedDue[12]
UserTagName
PSPTbl[0].PFS
PSPTbl[0].Time
PSPTbl[1].PFS
PSPTbl[1].Time
PSPTbl[2].PFS
PSPTbl[2].Time
PSPTbl[3].PFS
PSPTbl[3].Time
PSPTbl[4].PFS
PSPTbl[4].Time
PSPTbl[5].PFS
PSPTbl[5].Time
PSPTbl[6].PFS
PSPTbl[0].Time
PSPTbl[7].PFS
PSPTbl[7].Time
PSPTbl[8].PFS
PSPTbl[8].Time
PSPTbl[9].PFS
PSPTbl[9].Time
PSPTbl[10].PFS
PSPTbl[10].Time
PSPTbl[11].PFS
PSPTbl[11].Time
PSPTbl[12].PFS
PSPTbl[12].Time
PSPTbl[13].PFS
PSPTbl[13].Time
PSPTbl[14].PFS
PSPTbl[14].Time
PSPTbl[15].PFS
PSPTbl[15].Time
EEMagicNumber
Data Type
uint
uint
uint
uint
uint
float
float
uint
uint
uint
uint
float
uint
uint
uint
uint
uin
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
uint
Notes
Reload VolStop value when Totalizer reading counts down to zero 0 - No, 1 - Yes
Delay in seconds before Reload VolStop value when Totalizer reading counts down to zero [0-3600]
Enable or Disable every 10 seconds EEPROM backup (reserved for future version release)
Totalizer #2 reserved
Flow Pulse Output Mode (0=Disabled, 1=Enabled)
Start pulse output at flow [0-1.0 fraction notation %F.S.]
Units per pulse scaling
Number of ms output will be activated when pulse is developed
Pulse Output Reserved
0 - No conditioning, 1 - NRF, 2 - Running Average
Flow NRF Number of Samples [1 - 32]
Flow NRF Error Value [0.05 10.0] %F.S. (FN)
Flow NRF Time Interval [0-199], 0-disabled
Reading Damping 0-500 ms
Flow running average window [0-32] 0 - disable
Flow Linearizer: On (1), off (0)
Flow Signal Conditioner reserved
Flow Linearizer Index 0 PFS In (must be 0.0)
Flow Linearizer Index 0 PFS Out (must be 0.0)
Flow Linearizer Index 1 PFS In [0.0 - 1.0]
Flow Linearizer Index 1 PFS Out [0.0 - 1.0]
Flow Linearizer Index 2 PFS In [0.0 - 1.0]
Flow Linearizer Index 2 PFS Out [0.0 - 1.0]
Flow Linearizer Index 3 PFS In [0.0 - 1.0]
Flow Linearizer Index 3 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 4 PFS In [0.0 - 1.0]
Flow Linearizer Indes 4 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 5 PFS In [0.0 - 1.0]
Flow Linearizer Indes 5 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 6 PFS In [0.0 - 1.0]
Flow Linearizer Indes 6 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 7 PFS In [0.0 - 1.0]
Flow Linearizer Indes 7 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 8 PFS In [0.0 - 1.0]
Flow Linearizer Indes 8 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 9 PFS In [0.0 - 1.0]
Flow Linearizer Indes 9 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 10 PFS In [0.0 - 1.0]
Flow Linearizer Indes 10 PFS Out [0.0 - 1.0]
Serial Number for Mated Device
Device FS range in Std. L/min
Must be between [0 and 0.1] fraction %F.S. notation [0-1.0]
Flow Power Up delay [0-1200] sec.
Fluid Density g/L
Name of the Fluid used for Calibration
Name of person meter was calibrated by
Name of the Calibration Lab
Calibration date
Date Calibration due
User Defined Device Tag Name or Number
PSP Table Index 0 Set Point PFS (0.0-1.0)
PSP Table Index 0 Time (sec)
PSP Table Index 1 Set Point PFS (0.0-1.0)
PSP Table Index 1 Time (sec)
PSP Table Index 2 Set Point PFS (0.0-1.0)
PSP Table Index 2 Time (sec)
PSP Table Index 3 Set Point PFS (0.0-1.0)
PSP Table Index 3 Time (sec)
PSP Table Index 4 Set Point PFS (0.0-1.0)
PSP Table Index 4 Time (sec)
PSP Table Index 5 Set Point PFS (0.0-1.0)
PSP Table Index 5 Time (sec)
PSP Table Index 6 Set Point PFS (0.0-1.0)
PSP Table Index 6 Time (sec)
PSP Table Index 7 Set Point PFS (0.0-1.0)
PSP Table Index 7 Time (sec)
PSP Table Index 8 Set Point PFS (0.0-1.0)
PSP Table Index 8 Time (sec)
PSP Table Index 9 Set Point PFS (0.0-1.0)
PSP Table Index 9 Time (sec)
PSP Table Index 10 Set Point PFS (0.0-1.0)
PSP Table Index 10 Time (sec)
PSP Table Index 11 Set Point PFS (0.0-1.0)
PSP Table Index 11 Time (sec)
PSP Table Index 12 Set Point PFS (0.0-1.0)
PSP Table Index 12 Time (sec)
PSP Table Index 13 Set Point PFS (0.0-1.0)
PSP Table Index 13 Time (sec)
PSP Table Index 14 Set Point PFS (0.0-1.0)
PSP Table Index 14 Time (sec)
PSP Table Index 15 Set Point PFS (0.0-1.0)
PSP Table Index 15 Time (sec)
Number used to verify EEPROM integrity