beautypg.com

Dwyer GFT2 User Manual

Page 18

background image

APPENDIX A
GFT2 Totalizer Input/Output Flow Monitor/Controller EEPROM Variables

Index

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80

Name

BlankEEPROM[10]
SerialNumber[20]
ModelNumber[20]
SoftwareVer[10]
ManufReservedF1
ManufReservedF2
ManufReservedF7
ManufReservedF8
ReservedText[12]
ManufReservedF3
ManufReservedF4
ManufReservedF5
ManufReservedF6
ManufReservedUI1
ManufReservedUI2
ManufReservedUI3
ManufReservedUI4
ManufReservedSI1
ManufReservedSI2
ManufReservedSI3
TimeSinceCalHr
TProtectionCode
DeviceFunction
BaudRate
Address485
FlowUnits
UDUnitKfactor
UDUnitTimeBase
UDUnitDensity
KfactorMode
KfactorIndex
UserDefKfactor
DiagEventMask
PSP_Mode
SetPointPFS
DiagEventLatchMask
Reserved3
Reserved4
OptOut1_Config
OptOut2_Config
GLCD_Mode
GLCD_Static_Mode
GLCD_AUTO_Mode_Mask
Cycle_Time
GLCD_Contrast
GLCD_Reserved
GLCD_LED_PWM
PSP_StepMasc
PSP_LoopMode
Out_Scale_mA
Out_Offset_mA
In_mA_Mode
In_mA_Reserved
In_Scale_mA
In_Offset_mA
OutScaleV
OutOffsetV
InScaleV
InOffsetV
F_AlarmMode
F_LowAlarmPFS
F_HiAlarmPRS
F_AlmDelay
F_AlarmLatch
F_AlarmSpare
Total1_Mode
Total1_Config
Total1_FlowStart
Total1_VolStop
Total1_PowOnDelay
Total1_ValueLock
Total1_Volume_BkUp
Total1_AutoReset
Total1_AtoResetDelay
Total1_Reserved
Total2_Mode
Total2_Config
Total2_FlowStart
Total2_VolStop
Total2_PowOnDelay
Total2_Volume_BkUp

Data Type

char[10]
char[20]
char[20]
char[10]
float
float
float
float
char[12]
float
float
float
float
uint
uint
uint
uint
int
int
int
float
uint
uint
uint
char[4]
int
float
int
uint
uint
uint
float
uint
uint
float
uint
float
float
uint
uint
uint
uint
uint
uint
uint
uint
uint
uint
uint
float
float
uint
uint
float
float
float
float
float
float
uint
float
float
uint
uint
uint
uint
uint
float
float
uint
uint
float
uint
uint
uint
uint
uint
float
float
uint
float

Notes

Do not modify. Table Revision [PROTECTED]
Serial Number [PROTECTED]
Model Number [PROTECTED]
Firmware Version [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Reserved for Manufacture Specific Text Info [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Manufacture Specific float data [PROTECTED]
Time elapsed since last calibration in hours
Program Parameters Protection Code [0-255]
Device Function: 0-FlowMeter,1-FlowController
Comm. Interface Baud Rate Index [0-7]
Two hexadecimal characters address for RS485 only [01-FF]
Current Units of Measure [0-46]
Current Units of Measure [0-46]
User defined Unit Time base index:[0-3]
User defined Unit use density flag 1-'Y', 0-'N'
o-Disabled, 1-Internal, 2-User Defined
Internal K-Factor Index [0-21]
User defined K-Factor
Mask for Diagnostic Events: Clear bit -> mask
Mode for Program SP: 0-disabled, 1-enabled
Set Point value in %FS fraction notation [0.0 - 1.1]
Diagnostic Events Latch Mask register: Clear bit -> mask
Device General Reserved Settings
Device General Reserved Settings
Optical Output #1 Configuration (function)
Optical Output #2 Configuration (function)
Main Process screen mode: 0-Static, 1-Dynamic
Type of the static LCD screen: [0-3]
Type of the AUTO LCD screen: keeps mask for each variable
Time in seconds for each screen to be displayed in Dynamic mode
GLCD Contrast settings [1 - 16]
GLCD reserved settings
GLCD LED backlight PWM Duty cycle [1 - 16]
GLCD reserved settings
Program SP Loop mode:0-disabled, 1-enabled
Analog 4-20 mA Out Scale
Analog 4-20 mA Out Offset
Reserved Input parameter
Reserved Input parameter
Analog 4-20 mA Out Scale
Analog 4-20 mA Out Offset
Flow Analog 0-5/0-10 VDC Out Scale
Flow Analog 0-5/0-10 VDC Out Offset
Flow Analog 0-5/0-10 VDC Input Scale
Flow Analog 0-5/0-10 VDC Input Offset
Flow Alarm Mode (0=Disabled, 1=Enabled)
Low Flow Alarm in PFS [0-1.0 fraction notation %F.S.]
High Flow Alarm in PFS [0-1.0 fraction notation %F.S.]
Delay in seconds 0-3600 for Flow Alarm action
Flow Alarm Latch
Flow Alarm Spare settings
Totalizer #1 mode (0-Disabled, 1-Enabled)
Totalizer #1 configuration (0-Count Up)
Start tot. at flow [0-1.0 fraction notation %F.S.]
Limit volume in %s, 0 = disable
Totalizer #1 power on delay in second [0-3600]
Lock Totalizer #1 value (0-can be reset, 1-can not be reset)
Totalizer #1 backup volume in %s (saved every 6 minutes)
Reset Total. Volume value when Totalizer value equals Limit volume 0 - No, 1 - Yes
Delay in seconds before AutoReset will reset Totalizer#1 volume reading to zero [0-3600]
Totalizer#1 reserved
Totalizer#2 mode: (0-Disabled, 1-Enabled)
Totalizer#2 configuration (0-Count Up, 1-Count Down)
Start tot. at flow [0-1.0 fraction notation %F.S.]
Limit volume in %s, 0 = disable
Totalizer#2 power on delay in seconds [0-3600]
Totalizer#2 backup volume in %s (saved every 6 minutes)