PROFILE EXTRACTION
The Profile Extraction option on the main menu gives you the ability to extract historical interval profile data from ORION
water and gas endpoints for viewing in the ORION Profile Viewer software
OTEE:
N
Extracting historical interval profile data from an ORION Migratable endpoint can be performed via IR or RF
Extracting historical interval profile data from an ORION Classic endpoint can only be performed via IR
Figure 45: Profile Extraction screen
Interval Readings
An ORION Migratable water endpoint stores 90 days of hourly readings or 22 days of readings taken at 15 minute intervals
This chart shows the number of readings collected for meters set at 60 minute (hourly) intervals and at 15 minute (quarter
hourly) intervals:
Available Profile Data
Extraction Intervals
Hourly ReadsE:
1 Read per Hour
24 Reads per Day
15 Minute ReadsE:
4 Reads per Hour
96 Reads per Day
7 days
168 reads (24 x 7)
672 (96 x 7)
14 days
336 reads (24 x 14)
1344 (96 x 14)
30 days
720 reads (24 x 30)
2160 (96 x 22 5)
60 days
1440 reads (24 x 60)
2160 (96 x 22 5)
All/90 days
2160 reads (24 x 90)
2160 reads (96 x 22 5)
An ORION Classic endpoint is capable of storing more than 20,000 historical interval readings